Operating Instructions Thread tapping units/ Accessoriesr 01/09, Software 4.9
©
01.1994-2016 microtap GmbH
56
QUALITY CONTROL
Mz < Mz-min 025 Ncm
Meaning:
Remedy:
1. min-Mz not reached.
2. pilot hole was too big
3. Thread was already cut but not
counted
drill correct size pilot holes
C Hardwaretest
HARDWARE TEST FAILED
ERROR: 002
Meaning:
Remedy:
1. Off / on switch interval was too
short.
2. Error: Electronic defective
1. Switch machine off, wait 20 secs.,
switch on again or hardware error.
2.Machine needs to be repaired by
the service of microtap GmbH.
HARDWARETEST FAILED
ERROR: 003
Meaning:
Remedy:
Error: Electronic defective!
Machine needs to be repaired by the
service of microtap GmbH.
HARDWARETEST FAILED
ERROR: 004
Meaning:
Remedy:
Error: Electronic defective!
Machine needs to be repaired by the
service of microtap GmbH.
WARNING!
If the error message „ERROR“ appears the electronic of the machine is defective.
The machine is under high voltage. Only the service of microtap will open the
machine!
High voltage!
Note
If other error messages are displayed, please note them and call our Customer
Service Department for assistance.