Operating Instructions Thread tapping units/ Accessoriesr 01/09, Software 4.9
©
01.1994-2016 microtap GmbH
44
Start Fz/Sz +/- (Option ZAP)
Fz, Cal Sz see “START Fz”, Cal Sz see “START AUTO Sz”. To set the start position
+/- (mm) (leed angle - tolerance) confirm selector key (3), turn rotary knob (6) to set
the desired tolerance parameter and push selector key (3) to confirm.
-
The working mode is the same as at “START Fz”
Additional the machine does a comparision between the preset parameter of Cal
Sz and the tol/- (mm). (This makes it possible to find out differences in
the high, which are bigger than the preset tolerence parameter). The machine
displays an error message, that the tolerance was not kept. If the spindle does
not start in Sz, the pressure cylinder switches off and the spindle reverses. The
spindle goes back. The error message “QUALITY CONTROL NO LEAD ANGLE”
appears.
4.4.2.4 LUBRI.
CYCLE
ESCAPE->
MODE
TIMES
SME/DROP
1/1
ESCAPE->
MODE TIME
TIMES
SPRAY 010 1/1
Choose the lubricant unit with selector key (1). In case of a SPE set the duration of
the lubricant impulse with selector key (2) and rotary knob (6). Define frequency of
the lubricant cycle (every thread or every second thread etc.) with selector key (3)
and rotary knob (6).
4.4.2.5 CHIP
CLEARANCE
ESCAPE->
MODE
TIMES
NORMAL
OFF
Operating of selector key (1)
changes MODE NORMAL to
DEPTH
To change Chip Clearance NORMAL / Depth press selector button (1)
MODE NORMAL:
The input TIMES defines the number of the automatic cut
reliefs. (270° turn). The machine calculates relief depths. Push
selector key (3), select number with rotary knob (6) and confirm
with selector key (3).
ZAP.START Sz+/- with
Start pos. Control
Fz
Cal Sz+/- (mm)
XXX XX.X
XX.X
Display in working menu:
ST Fz/Sz