Operating Instructions Thread tapping units/ Accessoriesr 01/09, Software 4.9
©
01.1994-2016 microtap GmbH
36
3.5.4. Quality
monitoring
The quality status can be requested with “Q?”
Usually, a quality status is requested following an “X” (error) response.
The numeric code provides the following information:
- 0
= OK
-
1
=
command tapping depth not reached
-
2
=
tapping start fault
- 3
= (not
used)
-
4
=
process interruption by operator
-
5
=
error in reverse mode
- 6
= error
Sz
-
7
=
EMERGENCY STOP active
In special applications, further information can be retreived:
Quality status
Additional requests
Code used
1
tapping depth reached
t?
5
no. of reversing attempts
r?
6 Sz
s?
3.5.5. Remote control mode
The thread tapping machine can be remote controlled.
For this mode, the option ZAP has to be installed, see chapter “integrating options”.
Also, the operation via the machine control panel is then disabled.
Remote control ON:
H=1<CR>
Remote control OFF:
H=0<CR>
WARNING
For usage of the machine via remote control
Ensure that no person can enter the operating area of the machine when it is under
remote control by installing a fence, photo-electric guard or other means of barriers.