Power Over Ethernet Power View Pro User Guide
Copyright
2013
Microsemi
30
Rev.1.0, 17-Dec-13
Analog Mixed Signal Group
1 Enterprise, Aliso Viejo, CA 92656, USA; Phone (USA): (800) 713-4113, (ROW): (949) 221-7100 Fax: (949) 756-0308
Figure 4-6: Telnet Configuration and Maintenance Menu
Enable/Disable PoE Port
Enable/disable PoE port (Ethernet link remains enabled even when no
power is provided).
Download configuration file
from TFTP Server
Download unit configuration file from TFTP Server to the unit over the
network (please refer to Section 7 for more details).
After successful configuration download the internal Network Manager will
reset itself without affecting PoE functionality. However, network traffic
may be interrupted for several seconds while the internal Ethernet Switch
is reinitialized.
Upload configuration file to
TFTP Server
Upload unit configuration file from unit to TFTP Server over the network
(please refer to Section 7 for more details).
Software update menu
Performs software update by downloading new version from TFTP Server
(please refer to Section 8 for more details).
During the software update PoE functionality will remain active. However,
network traffic may be interrupted for several seconds.
Restore unit to factory default
(excluding IP configuration)
Restore unit configuration to factory default, leaving the IPv4/IPv6 network
configuration unchanged (as DHCP/Static IP, IP Address, etc.). Leaving
IP configuration unchanged maintains the option to access the unit over
the network as before.
Reset only Network Manager
Reset only the internal Network Manager is responsible for unit network
management interfaces such as Web, Telnet, SNMP, etc. Internal
Ethernet switch will also be reset (the network will be down for a few
seconds) leaving PoE power unchanged (powered PD devices will
continue normal operation as if no reset was done).
Reset unit
Reset the entire unit including the internal Network Manger, the PoE
controller, and the internal Ethernet Switch.
Enable/Disable auto ping to
Default Gateway to ensure
network connectivity
When enabled, the unit will verify proper network connectivity by pinging
default gateway every 12 seconds (IPv4 DGW or IPv6 DGW). After 10
consecutive ping failures, Network Management Module will reset itself
without affecting PoE ports.
NOTE:
To simplify locating the unit over the Network, upon power up the unit will send SysLog
broadcast messages (to any SysLog server on the network) reporting its IP network
configuration parameters, its MAC address, host name, etc.