NOTE:
You may need to add Telnet client service to Windows7 and Windows8. Please refer to the following links
for detailed instruction on how to add Telnet to Win7/Win8:
Win7:
http://technet.microsoft.com/en-us/library/cc771275%28v=ws.10%29.aspx
Win8:
http://www.sysprobs.com/install-and-enable-telnet-in-windows-8-use-as-telnet-client
7. Now that everything is ready, turn the unit off, wait 10 seconds, and turn it On. Wait for 15 seconds
before pressing Enter to start the Telnet session.
8. Type
passwordrecovery
as username and
passwordrecovery
as password. A recovery option will be
presented to the user. Press 'Y' to restore the unit to factory default configuration, causing the unit to
restart with default IPv4
192.168.0.50
and username as
admin
, and password as
password
.
Figure 9-3: Password Recovery by Restoring the Unit to Factory Default
NOTE:
NOTE1 - The entire recovery process from unit power-on until the username and password were applied
must take less than 90 seconds.
NOTE2 - Whenever one of the restrictions isn't meet (for example password was typed after 90 seconds
had passed) then the following message will be reported: