8 Software Upgrade
The following section describes how to perform unit software update.
8.1 Network Manager Software Update
The Network Manager provides the graphical (Web), textual (Telnet), SNMP interface between the unit and the
remote Network user, excluding PoE functionality which is performed by a dedicated Micro Controller, This
allows updating the Network Manager module without affecting active PoE PD devices.
Software update of the network manager interface is done over TFTP in a very similar way to Upload/Download
Unit Configuration.
1. Activate and run TFTP Server (provided on the CD or any other TFTP Server).
2. Verify that the firewall on the computer running TFTP Server is Off, or accepts incoming UDP traffic on
port 69.
Figure 8-1: NBTFTP Server
3. Copy the software update files (as in the example below) to TFTP Server root folder (for example
d:\temp).
4. Open a Telnet session with the unit. Type the username and password, and select the Configuration
and Maintenance Menu.
5. Select Software update menu.