4.2  Telnet 

– View Menu  

Telnet View option provides information on PoE ports status, network in-use parameters, and unit information. 
 

 

Figure 4-2: Telnet View Menu 

 

4.2.1  Telnet 

– View PoE Ports Status  

Telnet View PoE ports status provides network plus PoE power information about the various ports. 
 

 

Network 

– 

Reports Ethernet link speed (10/100/1000) and HD/FD connection type.

 

 

PoE 

– 

Power consumption of each remote PD device.

 

 

Total Power 

– 

Total power consumption of all PDs from all active PoE ports plus maximum available 

power. 

 

 

Figure 4-3: Telnet View PoE Ports Status

 

 

 

 

 

 

 

 

Содержание Outdoor Power View Pro

Страница 1: ...Power over Ethernet Outdoor Power View Pro User Guide Version 1 1 Catalog Number PDS_NMS_UG 2014 Microsemi Corporation All rights reserved This document is subject to change without notice...

Страница 2: ...308 Acknowledgements All other products or trademarks are property of their respective owners The product described by this manual is a licensed product of Microsemi Abbreviations and Terminology Abbr...

Страница 3: ...ION WEB PAGE 16 3 3 1 Security Configuration Configure unit user name and password for remote Web or Telnet access 16 3 3 2 Network Configuration configure unit IPv4 IPv6 and host name parameters 16 3...

Страница 4: ...PASSWORD 40 9 1 SUMMARIZED USERNAME PASSWORD RECOVERY PROCEDURE FOR EXPERTS 40 9 2 DETAILED STEP BY STEP USERNAME PASSWORD RECOVERY PROCEDURE 40 10 TROUBLESHOOTING 43 List of Figures FIGURE 3 1 CONFIG...

Страница 5: ...E MENU 30 FIGURE 5 1 SNMPC NETWORK MANAGEMENT TOOL 31 FIGURE 5 2 ENABLE SNMPV2 SNMPV3 AND POE TRAPS 32 FIGURE 5 3 MIB TREE STRUCTURE 33 FIGURE 7 1 NBTFTP SERVER 36 FIGURE 7 2 UPLOAD UNIT CONFIGURATION...

Страница 6: ...ing Device list o PDS 102GO AC M The PDS 102GO AC M is an outdoor PoE switch that enables connecting two powered devices to the network The switch will deliver PoE power up to 30W per device In additi...

Страница 7: ...TFTP Section 8 Software upgrade Section 9 Recovering from unknown username password Section 10 Troubleshooting 1 4 Conventions The various conventions used in defining commands and examples are given...

Страница 8: ...Pv4 32 bit long IP address IPv6 128 bit long IP address DHCPv4 Dynamic IPv4 Host Configuration Protocol DHCPv6 Dynamic IPv6 Host Configuration Protocol PoE Power over Ethernet NTP Network Time Protoco...

Страница 9: ...long with multiple access options Supported network IP protocols o IPv4 IP address is made out of 32 bits static DHCPv4 o IPv6 IP address is made out of 128 bits static DHCPv6 Access Options o HTTP We...

Страница 10: ...alid remote user access initial DHCPv4 v6 address etc 2 3 Ethernet Switch Network Capabilities 10M 100M 1000Mbit Half Duplex Full Duplex Ethernet speed 8K internal MAC address lookup engine Auto MDIX...

Страница 11: ...tring password can be easily intercepted by any network sniffer device SNMP v3 Resolves SNMPv1 v2 security issues by adding authentication and encryption to SNMP packets 2 7 Default unit IP username a...

Страница 12: ...rnet ports Open your Web browser and type 192 168 0 50 in the top address field Default web username is admin and default password is password Selecting the Configuration option on the menu will revea...

Страница 13: ...9 756 0308 3 2 Main Web Page The main Web page is used to monitor unit status PoE ports status such as Ethernet Link connection speed PoE power consumption and total unit PoE power consumption The Web...

Страница 14: ...upper power indicator is on No Ethernet link lower link indicator image is gray PoE port is enabled green line around the RJ45 connector PoE power is provided upper power indicator is on Ethernet link...

Страница 15: ...and all ports total PoE power consumption 3 2 3 Main Web Page Ports Status Reset Figure 3 6 Ports Status Reset Port Status Port status reports for each port Ethernet link speed 10 100 1000MB and type...

Страница 16: ...e and password for remote Web or Telnet access Figure 3 7 Security Configuration User Name Unit user name for remote Web Telnet access Password Unit password for remote Web Telnet access 3 3 2 Network...

Страница 17: ...iven a specific IP address Please note that IPv6 uses the FQDN terminology as host name 3 3 3 Network Services Configuration IPv4 IPv6 Figure 3 9 Network Services Configuration DNS Server 1 DNS Server...

Страница 18: ...community string For example private SNMPv2 TRAP Community SNMPv2 Trap community string For example public MIB II SysContact SNMP MIB II system contact OiD string For example John MIB II SysName SNMP...

Страница 19: ...tion Mode None no authentication or encryption no security equivalent to SNMPv2 MD5 MD5 authentication with no encryption packet can t be changed however it can easily be analyzed by network sniffers...

Страница 20: ...set Unit Reset the internal Network Manager internal PoE controller and internal Ethernet Switch o Reset to Factory Default Reset unit configuration to factory default excluding unit network configura...

Страница 21: ...to 24 hours One or more PoE ports can be assigned to each PoE activation scheme NOTE For Automatic Weekly Schedule PoE Port Activation to function properly an NTP Server must be configured see Config...

Страница 22: ...tialized NOTE For Automatic Weekly Schedule PoE Port Reset to function properly an NTP Server must be configured see Configuration Web Page providing correct GMT time Please make sure that a green OK...

Страница 23: ...y Default Restore unit configuration to factory default leaving IPv4 IPv6 network configuration unchanged as DHCP Static IP IP Address etc maintaining the option to access the unit over the network as...

Страница 24: ...v4 default gateway for example 172 5 6 1 3 5 1 2 Information Web Page In Use DNS DNS 1 First in use Domain Name Server IPv4 IPv6 responsible for converting URL names such as my computer com to IPv4 IP...

Страница 25: ...roduct Information Part Number Unit marketing part number Serial Number Unit production serial number Production Number Unit internal production number for internal use Software Version Unit Network M...

Страница 26: ...l appear to the second Telnet user requesting the user to try and reconnect over Telnet a little later Non active Telnet session no keystroke from remote user will be terminated automatically after th...

Страница 27: ...orts status network in use parameters and unit information Figure 4 2 Telnet View Menu 4 2 1 Telnet View PoE Ports Status Telnet View PoE ports status provides network plus PoE power information about...

Страница 28: ...actual in use IPv4 address IPv4 mask and default gateway In use IPv6 Network Parameters Reports if DHCPv6 is enabled or disabled and the actual in use IPv6 address IPv6 prefix and default gateway Plea...

Страница 29: ...sible for PoE functionality CPU Rev FLAH RAM For internal use only System Up Time The time passed since the unit was reset System GMT time Unit GMT time as it was obtained from NTP Server System Local...

Страница 30: ...twork traffic may be interrupted for several seconds Restore unit to factory default excluding IP configuration Restore unit configuration to factory default leaving the IPv4 IPv6 network configuratio...

Страница 31: ...Openview IBM Tivoli SNMPc etc Figure 5 1 SNMPc Network Management Tool NOTE Due to security concerns the unit is shipped with the SNMP disabled Prior to enabling SNMP please modify SNMP community stri...

Страница 32: ...nit consumes over xy of total unit power or unit now consumes less than xy of total unit power please enable PoE Notifications see image below Figure 5 2 Enable SNMPv2 SNMPv3 and PoE traps 5 2 SNMP MI...

Страница 33: ...OiD is accessed as a two dimensional array table The second section deals with the power source that is responsible for providing power to a group of PoE ports It enables reading total power consumpt...

Страница 34: ...w summarizes the various SysLog messages that may be sent by the SysLog Server Msg ID Description Information to be provided Comments 0 System UP Will be send each time power is provided to the unit o...

Страница 35: ...E controller has no firmware will be sent in case PoE controller firmware will be erased or become corrupted 11 Invalid Telnet remote user tried to access the unit by Telnet with incorrect username pa...

Страница 36: ...provided inside the CD supports only IPv4 2 Verify that the firewall on the computer running TFTP Server is Off or accepts incoming UDP traffic on port 69 Figure 7 1 NBTFTP Server 3 Set TFTP Server ro...

Страница 37: ...7 3 Download Unit Configuration 3 Type the TFTP Server IPv4 IPv6 address file name for example param txt and press Enter to download the unit configuration file from the TFTP Server root folder to th...

Страница 38: ...a dedicated Micro Controller This allows updating the Network Manager module without affecting active PoE PD devices Software update of the network manager interface is done over TFTP in a very simila...

Страница 39: ...type the TFTP Server IP Address see image below Figure 8 3 Selecting Software Update from the Configuration Menu 7 The files to be updated will be validated first and only then does the actual softwa...

Страница 40: ...y of the PD devices 3 Turn unit power Off Wait 10 seconds or so to make sure the unit is completely off 4 Apply back power to the unit And wait around 15 seconds 5 The entire procedure described below...

Страница 41: ...indows7 Windows8 machine For Windows 7 Click Start and type cmd For Windows 8 Press the Windows key R key and type cmd 5 Type ipconfig to identify the virtual interface index of your IPv6 Link Local a...

Страница 42: ...ready turn the unit off wait 10 seconds and turn it On Wait for 15 seconds before pressing Enter to start the Telnet session 8 Type passwordrecovery as username and passwordrecovery as password A reco...

Страница 43: ...FTP cannot be performed 1 Use the Unit Ping utility to ping the host running the TFTP Server application 2 Turn off firewall or enable UDP port 69 3 Verify that the appropriate update files package wa...

Страница 44: ...g to sale and or use of Microsemi products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual...

Отзывы: