Panel Functions 73
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX
Operator’s Manual SOLID F40
Edition 1.1
5.23. Image Shifting to the X-Direction
This function shifts the print image in relation to the paper to the
X-direction (crosswise the print direction). Because the paper feed
is always centered to the middle in the SOLID F40, the image
shifting might be necessary when using e.g. special paper formats
to shift the X-coordinate zero to the left paper edge.
ON LINE
SAVE
SAVE
SAVE
MENU
SAVE
ON LINE
Panel display
[SOLID F40 ]
[Menu Level 1
]
)
)
)
[Engine
]
[Resolution
]
)
)
)
[Image X-Pos.
]
[Image X-Pos.
xxx ]
)
)
)
[Image X-Pos. 160
]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
Press one of the ARROW keys until
[Engine ] is displayed.
Press one of the ARROW keys until
[Image X-Pos.] is displayed.
The panel function Image Shifting to the
X-Direction is selected.
xxx = currently set value.
(Default value =128).
Operating one of the ARROW keys the
value for the image shift can be altered.
Values from 0 up to 254 are settable,
so a max. image shifting of appr. ±1 ¼
Inch (approx. ±32 mm) can be reached.
Now the new image X-Position is saved
In addition this new value can be saved
as setup value (using the SAVE key),
before the printer is turned ON LINE
again.