172
M204 SPECIFICATIONS: Hardware Specifications
M204 LED’s
PWR
Power supply.
STAT
System status.
ERR
System error.
NET
Data to network.
The seven-stage power-on self test performs diagnostics on the
processor, RAM, ROM, EEPROM, serial ports, parallel ports,
and network interface. The STAT, ERR, and NET LEDs indicate
which test is currently in progress.
Run Mode is the normal operating state of the M204. Auto-Reset
mode is entered when the watchdog timer is triggered and the
Print Server has reset itself. In either mode, the STAT LED
flashes differently depending on whether the unit’s IP address is
configured and COM1 monitor is active.
Table 8:
LED Patterns
STAT
ERR
NET
Mode
STAT
ERR
NET
Mode
ON
ON
ON
PIA/CPU Test
FLASH
OFF
-
Run Mode
ON
OFF
ON
RAM Test
FLASH
ON
-
Auto-Reset Mode
ON
OFF
OFF
ROM Test
OFF
FLASH
ON
License Violation
ON
ON
OFF
EEPROM Test
FLASH
FLASH
OFF
Firmware Panic
OFF
ON
OFF
COM1/COM2 Test
OFF
FLASH
OFF
Watchdog Alarm
OFF
ON
ON
Network Interface Test ON
FLASH
OFF
Spurious Interrupt
OFF
OFF
ON
PRN1/PRN2 Test
ON
FLASH
ON
Hardware Exception
LED Indicators
Power-on Self Test
Run and Auto-Reset
Modes
Содержание M204
Страница 8: ...vi LIST OF TABLES...
Страница 12: ...4 PREFACE Computer Entry and Display Conventions...
Страница 22: ...14 GETTING TO KNOW THE M204 Overview of Print Server Installation...
Страница 70: ...62 CONFIGURING THE M204 FOR NOVELL Host Configuration...
Страница 124: ...116 USING NPWIN Starting a NPWin Session With An Unconfigured Unit...
Страница 125: ...117...
Страница 126: ...118...
Страница 154: ...146 USING THE M204 S ADDITIONAL OPTIONS IP Routing...
Страница 166: ...156 TROUBLESHOOTING THE M204 Windows Problems...
Страница 192: ...182 GLOSSARY B A C...
Страница 196: ...186 APPENDIX A Planning Your Print Setup...
Страница 204: ...194 INDEX...