Control board L023
Micronova
ENG
8.5 Working mode
If the lighting phase is successful, the stove transitions to the working phase which
represents the normal functioning mode.
If the flue temperature is higher than Pr15 the exchangers are enabled.
Exchangers no. 2 and no. 3 are activate only if they have been enabled.
fig. 18
8.6 Adjusting the room temperature setting
To adjust the room temperature setting, simply press the P1 and P2 buttons. The display will
indicate the current status of the SET temperature,
figure 19.
U
S
E
R
O
P
E
R
A
T
IN
G
M
O
D
E
8.4 Lighting failure
Once the Pr01 time has elapsed, if the flue temperature has not reached the minimum
temperature allowed, setting Pr13, reached with a gradient of 2°VC/min, the alarm will
sound.
fig. 19
8.7 How to use the external thermostat/programmable thermostat
If you wish to use an external room thermostat, connect to the TERM clips (connetor
CN7 pin 7
-
8).
•
termostato esterno
: on the stove select a SET temperature equal to 7°C.
•
cronotermostato esterno
: on the stove select a SET temperature equal to 7°C
and disable the crono function in the 03
-
01 menu.
The stove will be enabled while the stove is on and at the end of contact.