8.8 The room temperature reaches the SET temperature
Once the room temperature reaches the set temperature or the flue
temperature has reached Pr13, the heating power is automatically
brought to the lowest point, MODULATION condition, see
figure
20.
OPERATING
STATUS
WORKING
SHUT DOWN
ASHPAN
CLEANING
WORKING
fig. 20
If standby mode has been activated, the stove will switch off with a
delay equal to the Pr44 time after having reached the set temperature.
The reignition will occur when the following conditions have been
met:
T
ambiente >
(T
SET
+ Pr43)
8.9 Cleaning the ashpan
During normal operation in the working phase, “CLEAN ASHPAN” mode is
activated at intervals established by the Pr03 setting and for the amount of time
established by the Pr12 setting.
fig. 21