Micronova S.r.l.
-
Via A. Niedda, 3
-
35010 Vigonza (PD)
-
+39 049 8931563
-
+39 049 8931346
date 11/06/2016
page 51 of 83
Control board L023
Micronova
ENG
A
L
A
R
M
S
10.3 Ignition failure alarm
This alarm sounds when the lighting phase fails.
In such cases the stove will immediately begin to shut down.
ALARMS
IGNITION
FAILURE
SHUT DOWN
WHILE
WORKING
DEPRESSION
FAILURE
10.4 Shut down during working mode alarm
If the flame goes out during working mode and the flue temperature
drops below the minimum working threshold (parameter Pr113), the
alarm sounds as illustrated in
figure 30.
In such cases the stove will immediately begin to shut down.
fig. 29
fig. 30
10.5 Pressure switch for auger safety alarm
If the pressure switch measures a pressure lower than the threshold ,it
intervenes in order to stop the auger (when the auger is working) and, at
the same time, through the AL2 clip in CN4, it allows the control board
to acquire this change in state. On the display, the message “Alarm Dep
Fail” will appear and the system will stop.
fig. 31