Micronova S.r.l.
-
Via A. Niedda, 3
-
35010 Vigonza (PD)
-
+39 049 8931563
-
+39 049 8931346
date 11/06/2016
page 33 of 83
Control board L023
Micronova
ENG
7.6 Menu 05
-
stand
-
by mode
Activate the “STANDBY” mode which switches off the stove once the room
temperature has exceeded the SET temperature for longer than the amount of time
defined by Pr44.
After the shutdown has been completed in cases as such, reignition can occur only
when the following conditions have been met:
T
SET
< (T
ambiente
-
Pr43)
7.7 Menu 06
-
alarm mode
When “OFF” disables the sound.
U
S
E
R
M
E
N
U
7.5 Menu 04
-
language selection
It allows you to select the dialogue language among the list of available languages.
SUGGESTION: in an attempt to avoid confusion and unwanted switch
-
on and
switch
-
off stages, activate only one program at a time if you are unsure of exactly
what is that you wish to obtain.
Deactivate the daily program if you wish to use the weekly program. Always keep the
weekend program disabled if using the weekly program in programs 1, 2, 3 and 4.
Activate the weekend program only after deactivating the weekly program.
Submenu 03
-
04
-
program week
-
end
It allows you to enable, disable and set the functions of the programmable
thermostat for the weekend (days 5 and 6, that is Saturday and Sunday).