Microlink 8890X Series Скачать руководство пользователя страница 9

Infrared Intelligent High Speed Dome Camera Operating Manual

8

Binary code      Address

Binary code      Address

Binary code      Address

Binary code      Address

153

157

161

165

169

173

177

181

185

189

193

197

201

205

209

213

217

221

225

229

233

237

241

245

249

253

10011001

10111001

10000101

10100101

10010101

10110101

10001101

10101101

10011101

10111101

10000011

10100011

10010011

10110011

10001011

10101011

10011011

10111011

10000111

10100111

10010111

10110111

10001111

10101111

10011111

10111111

01011001

01111001

01000101

01100101

01010101

01110101

01001101

01101101

01011101

01111101

01000011

01100011

01010011

01110011

01001110

01101011

01011011

01111011

01000111

01100111

01010111

01110111

01001111

01101111

01011111

01111111

154

158

162

166

170

174

178

182

186

190

194

198

202

206

210

214

218

222

226

230

234

238

242

246

250

254

11011001

11111001

11000101

11100101

11010101

11110101

11001101

11101101

11011101

11111101

11000011

11100011

11010011

11110011

11001011

11101011

11011011

11111011

11000111

11100111

11010111

11110111

11001111

11101111

11011111

11111111

155

159

163

167

171

175

179

183

187

191

195

199

203

207

211

215

219

223

227

231

235

239

243

247

251

255

00111001

00000101

00100101

00010101

00110101

00001101

00101101

00011101

00111101

00000011

00100011

00010011

00110011

00001011

00101011

00011011

00111011

00000111

00100111

00010111

00110111

00001111

00101111

00011111

00111111

00000000

156

160

164

168

172

176

180

184

188

192

196

200

204

208

212

216

220

224

228

232

236

240

244

248

252

1

Software

    

 

modify

2.6  Control equipment

According to users’ need, below are the equipments normally used

Control borad 

PC

Video capture card

 

DVR 

tester

specially for project

 

Содержание 8890X Series

Страница 1: ...Infrared High Speed Dome Camera Fourth generation IV Operating manual 8890X series Version V2 0...

Страница 2: ...instant discharge lightning technology which can prevent the lightning under 500W power surge and other kinds of pulse of high voltage to damage the interior of the camera 4 In order to protect the c...

Страница 3: ...Control equipment 2 7 Boot initialization 2 8 Basic operation 3 AUTOMATIC OPERATION SETTING menu operation 3 1 PRESET POINT setting 3 2 LEFT RIGHT SCAN setting 3 3 CRUISE SCAN setting 3 4 PATTERN SCAN...

Страница 4: ...l 3 1 Installation and debugging of Infrared High Speed Dome Camera 1 1 Infrared high speed component name Frontal outline drawing 1 2 Installing hole size figure Whole set size mm Installing hole siz...

Страница 5: ...the left of prevent lighting plate 1 3 7 if the distance between the machine and control equipment over 500 meters connect 485 matching resistor jumpers on the prevent lighting plate to the two pins...

Страница 6: ...to 8 protected areas Can be set to 6 numbers password Date time positon temperature etc Support 4ways output 2ways input colse open optional 40 60 95 no condensation 5 Heating 48 Cooling IP65 400 380...

Страница 7: ...Address protocol baud rate setting After machine installed be sure the ball machine set DIP switch address code protocol baud rate is fully consistent with the control equipment Our High speed Demo c...

Страница 8: ...11100 01000010 01100010 01010010 01110010 01001010 01101010 01011010 01111010 01000110 01100110 01010110 01110110 01001110 01101110 01011110 01111110 01000001 01100001 01010001 01110001 01001001 01101...

Страница 9: ...170 174 178 182 186 190 194 198 202 206 210 214 218 222 226 230 234 238 242 246 250 254 11011001 11111001 11000101 11100101 11010101 11110101 11001101 11101101 11011101 11111101 11000011 11100011 1101...

Страница 10: ...t of the camera s initialization as picture 1 At the mean while the PTZ starts check up down left and right after checking will show system initialization success Then it will standby picture 2 or get...

Страница 11: ...TIC OPERATION SETTING menu operation Attention the manual explanation sequences are based on the practicability of camera function not based on the menu Please choose the sections you need Enter camer...

Страница 12: ...elect the preset number up or down the joystick to select 1 220 preset point number 2 Title Press Iris to enter and edit the title up or down the joysticks to choose numbers letters or characters Left...

Страница 13: ...ers press IRIS to save after edit then return 3 Set start press IRIS to set scan start move PTZ to choose the start on the left press IRIS again to confirm and return 4 Set stop press IRIS to set scan...

Страница 14: ...preset point control lever up and down to choose second 1 255 every group can up to set 32 preset point same with other preset points setting press IRIS to save after edit then return Picture 9 shows...

Страница 15: ...ows as 11 Detail operations 1 Time number click IRIS to choose time number move joystick up or down to choose 1 4 number 2 Start time click IRIS to set start time Dome camera can set time in 24 hours...

Страница 16: ...to 90 degree vertically 2 Auto focus mode click IRIS to enter move joystick up or down to choose iris focus close all For example choose iris then lens focus will not change when pan tilt move And th...

Страница 17: ...up or down to choose high or low speed Click IRIS to save and return 2 Digital zoom click IRIS to set digital zoom Move the joystick up or down to open or close digital zoom function 3 Focus limit cl...

Страница 18: ...brighter the image is 6 Digi slow shutter set digital shutter to open or close 7 Day night mode make the camera and IR led change day night mode by force to three modes auto night and day 4 3 WHITE BA...

Страница 19: ...to choose the object needed to cover and be sure the object is in the middle of the monitor again click IRIS to set the size of the area It appears a black rectangular area in the middle At this momen...

Страница 20: ...nal choosing close means not display if choose the seconds it means it will close after the time you choose The others have the same setting as above Global Settings click IRIS can to modify all proje...

Страница 21: ...s IRIS to entry the restore factory setting all the parameter which users set will recover the original one However the system setting pantilt setting alarm setting will not change 7 System restart Pr...

Страница 22: ...etup 1 4 group left right scan setup 1 4 group pattern setup 1 220pcs preset and close shaking the rocker up or down could select one of them close means don t operate anything After setting press IRI...

Страница 23: ...Power cable in short circuit or open circuit Address code protocol baud rate setting is incorrect RS485 length is more than 500m RS485 connection is not good Power is not strong enough Belt is loose o...

Страница 24: ...Before using the camera please read the factory settings of the user manual carefully Power AC200V 50HZ Address1 Protocol PELCO D Baut Rate 2400bps...

Отзывы: