Microlink 8890X Series Скачать руководство пользователя страница 8

Infrared Intelligent High Speed Dome Camera Operating Manual

7

The Infrared 
setup

2.5

Address DIP table

1 means ON

0 means OFF

Binary code      Address

Binary code      Address

Binary code      Address

Binary code      Address

10000000

10100000

10010000

10110000

10001000

10101000

10011000

10111000

10000100

10100100

10010100

10110100

10001100

10101100

10011100

10111100

10000010

10100010

10010010

10110010

10001010

10101010

10011010

10111010

10000110

10100110

10010110

10110110

10001110

10101110

10011110

10111110

10000001

10100001

10010001

10110001

10001001

10101001

01000000
01100000
01010000
01110000
01001000
01101000
01011000
01111000
01000100
01100100
01010100
01110100
01001100
01101100
01011100
01111100
01000010
01100010
01010010
01110010
01001010
01101010
01011010
01111010
01000110
01100110
01010110
01110110
01001110
01101110
01011110
01111110
01000001
01100001
01010001
01110001
01001001
01101001

11000000

11100000

11010000

11110000

11001000

11101000

11011000

11111000

11000100

11100100

11010100

11110100

11001100

11101100

11011100

11111100

11000010

11100010

11010010

11110010

11001010

11101010

11011010

11111010

11000110

11100110

11010110

11110110

11001110

11101110

11011110

11111110

11000001

11100001

11010001

11110001

11001001

11101001

00100000

00010000

00110000

00001000

00101000

00011000

00111000

00000100

00100100

00010100

00110100

00001100

00101100

00011100

00111100

00000010

00100010

00010010

00110010

00001010

00101010

00011010

00111010

00000110

00100110

00010110

00110110

00001110

00101110

00011110

00111110

00000001

00100001

00010001

00110001

00001001

00101001

00011001

Содержание 8890X Series

Страница 1: ...Infrared High Speed Dome Camera Fourth generation IV Operating manual 8890X series Version V2 0...

Страница 2: ...instant discharge lightning technology which can prevent the lightning under 500W power surge and other kinds of pulse of high voltage to damage the interior of the camera 4 In order to protect the c...

Страница 3: ...Control equipment 2 7 Boot initialization 2 8 Basic operation 3 AUTOMATIC OPERATION SETTING menu operation 3 1 PRESET POINT setting 3 2 LEFT RIGHT SCAN setting 3 3 CRUISE SCAN setting 3 4 PATTERN SCAN...

Страница 4: ...l 3 1 Installation and debugging of Infrared High Speed Dome Camera 1 1 Infrared high speed component name Frontal outline drawing 1 2 Installing hole size figure Whole set size mm Installing hole siz...

Страница 5: ...the left of prevent lighting plate 1 3 7 if the distance between the machine and control equipment over 500 meters connect 485 matching resistor jumpers on the prevent lighting plate to the two pins...

Страница 6: ...to 8 protected areas Can be set to 6 numbers password Date time positon temperature etc Support 4ways output 2ways input colse open optional 40 60 95 no condensation 5 Heating 48 Cooling IP65 400 380...

Страница 7: ...Address protocol baud rate setting After machine installed be sure the ball machine set DIP switch address code protocol baud rate is fully consistent with the control equipment Our High speed Demo c...

Страница 8: ...11100 01000010 01100010 01010010 01110010 01001010 01101010 01011010 01111010 01000110 01100110 01010110 01110110 01001110 01101110 01011110 01111110 01000001 01100001 01010001 01110001 01001001 01101...

Страница 9: ...170 174 178 182 186 190 194 198 202 206 210 214 218 222 226 230 234 238 242 246 250 254 11011001 11111001 11000101 11100101 11010101 11110101 11001101 11101101 11011101 11111101 11000011 11100011 1101...

Страница 10: ...t of the camera s initialization as picture 1 At the mean while the PTZ starts check up down left and right after checking will show system initialization success Then it will standby picture 2 or get...

Страница 11: ...TIC OPERATION SETTING menu operation Attention the manual explanation sequences are based on the practicability of camera function not based on the menu Please choose the sections you need Enter camer...

Страница 12: ...elect the preset number up or down the joystick to select 1 220 preset point number 2 Title Press Iris to enter and edit the title up or down the joysticks to choose numbers letters or characters Left...

Страница 13: ...ers press IRIS to save after edit then return 3 Set start press IRIS to set scan start move PTZ to choose the start on the left press IRIS again to confirm and return 4 Set stop press IRIS to set scan...

Страница 14: ...preset point control lever up and down to choose second 1 255 every group can up to set 32 preset point same with other preset points setting press IRIS to save after edit then return Picture 9 shows...

Страница 15: ...ows as 11 Detail operations 1 Time number click IRIS to choose time number move joystick up or down to choose 1 4 number 2 Start time click IRIS to set start time Dome camera can set time in 24 hours...

Страница 16: ...to 90 degree vertically 2 Auto focus mode click IRIS to enter move joystick up or down to choose iris focus close all For example choose iris then lens focus will not change when pan tilt move And th...

Страница 17: ...up or down to choose high or low speed Click IRIS to save and return 2 Digital zoom click IRIS to set digital zoom Move the joystick up or down to open or close digital zoom function 3 Focus limit cl...

Страница 18: ...brighter the image is 6 Digi slow shutter set digital shutter to open or close 7 Day night mode make the camera and IR led change day night mode by force to three modes auto night and day 4 3 WHITE BA...

Страница 19: ...to choose the object needed to cover and be sure the object is in the middle of the monitor again click IRIS to set the size of the area It appears a black rectangular area in the middle At this momen...

Страница 20: ...nal choosing close means not display if choose the seconds it means it will close after the time you choose The others have the same setting as above Global Settings click IRIS can to modify all proje...

Страница 21: ...s IRIS to entry the restore factory setting all the parameter which users set will recover the original one However the system setting pantilt setting alarm setting will not change 7 System restart Pr...

Страница 22: ...etup 1 4 group left right scan setup 1 4 group pattern setup 1 220pcs preset and close shaking the rocker up or down could select one of them close means don t operate anything After setting press IRI...

Страница 23: ...Power cable in short circuit or open circuit Address code protocol baud rate setting is incorrect RS485 length is more than 500m RS485 connection is not good Power is not strong enough Belt is loose o...

Страница 24: ...Before using the camera please read the factory settings of the user manual carefully Power AC200V 50HZ Address1 Protocol PELCO D Baut Rate 2400bps...