4.Time setting:

 Press “IRIS+”to enter the time setting system. Can set year, month, date, minute and second. 

                                 However, the date can be set between 2000-2099.Shaking the rocker up or down can be set
                                 the last two figure of the year, left or right can change the looking area. It is the same setting 
                                 method for month and date. Change the time by sharking the rocker. See 

 25:

5.Reset the password:

 Press “IRIS+”to enter password setting, which made into 6pcs character. Remind

                                                 “entry the new password”, shaking the rocker up or down can select the figure, 
                                                 letter in small or capital, symbol and so on to make as your password. Shacking 
                                                 by left or right can change the edited area. After setting it will remind you 
                                                 automatically for “confirm the new password”

then entry again, which must be

                                                 the same password as last time you entries. Otherwise it will told you“password 
                                                 error”. After setting password, you need to entry it every time when you login into
                                                 the menu. Ref picture 26:

6. FACTORY DEFAULT:

 Press“IRIS+”to entry the restore factory setting, all the parameter which users 

                                                 set will recover the original one. However, the system setting, pantilt setting, alarm 
                                                 setting will not change.

7.System restart:

 Pressing“IRIS+”will turn off the system and self-checking.

Picture

Picture 25time setting: 

p

ic

tu

re

 

2

6

P

in c
o

d

e s
e

tin

g

:

p

ic

tu

re 2
7

C

a

m

e

ra i
n

fo

rm

a

tio

n

:

 

Attention

 

Setting the password can avoid to the parameter being revised illegally.Once you set the password,you 

  can’t set the preset when it’s in standby.

Infrared Intelligent High Speed Dome Camera Operating Manual

20

                                         address via move the rocker up and down. After choose pls press”Iris+”for preserving and return. At this time
                                         you also need to do a same change for address on control device, otherwise maybe you can’t go on operating.

 

2.Camera name:

 press “IRIS+”to enter the name set interface, shaking the rocker up or down to choose 

                                    figure, character and so on; shaking to left or right can change the edited area or revise 
                                    the character. After the edition please press the “IRIS+”to save and return.

3. Language selection:

 Press“IRIS+”to enter the language set system, and choose the “Chinese” or 

                                                 “English” by shaking the rocker up or down.

Содержание 8890X Series

Страница 1: ...Infrared High Speed Dome Camera Fourth generation IV Operating manual 8890X series Version V2 0...

Страница 2: ...instant discharge lightning technology which can prevent the lightning under 500W power surge and other kinds of pulse of high voltage to damage the interior of the camera 4 In order to protect the c...

Страница 3: ...Control equipment 2 7 Boot initialization 2 8 Basic operation 3 AUTOMATIC OPERATION SETTING menu operation 3 1 PRESET POINT setting 3 2 LEFT RIGHT SCAN setting 3 3 CRUISE SCAN setting 3 4 PATTERN SCAN...

Страница 4: ...l 3 1 Installation and debugging of Infrared High Speed Dome Camera 1 1 Infrared high speed component name Frontal outline drawing 1 2 Installing hole size figure Whole set size mm Installing hole siz...

Страница 5: ...the left of prevent lighting plate 1 3 7 if the distance between the machine and control equipment over 500 meters connect 485 matching resistor jumpers on the prevent lighting plate to the two pins...

Страница 6: ...to 8 protected areas Can be set to 6 numbers password Date time positon temperature etc Support 4ways output 2ways input colse open optional 40 60 95 no condensation 5 Heating 48 Cooling IP65 400 380...

Страница 7: ...Address protocol baud rate setting After machine installed be sure the ball machine set DIP switch address code protocol baud rate is fully consistent with the control equipment Our High speed Demo c...

Страница 8: ...11100 01000010 01100010 01010010 01110010 01001010 01101010 01011010 01111010 01000110 01100110 01010110 01110110 01001110 01101110 01011110 01111110 01000001 01100001 01010001 01110001 01001001 01101...

Страница 9: ...170 174 178 182 186 190 194 198 202 206 210 214 218 222 226 230 234 238 242 246 250 254 11011001 11111001 11000101 11100101 11010101 11110101 11001101 11101101 11011101 11111101 11000011 11100011 1101...

Страница 10: ...t of the camera s initialization as picture 1 At the mean while the PTZ starts check up down left and right after checking will show system initialization success Then it will standby picture 2 or get...

Страница 11: ...TIC OPERATION SETTING menu operation Attention the manual explanation sequences are based on the practicability of camera function not based on the menu Please choose the sections you need Enter camer...

Страница 12: ...elect the preset number up or down the joystick to select 1 220 preset point number 2 Title Press Iris to enter and edit the title up or down the joysticks to choose numbers letters or characters Left...

Страница 13: ...ers press IRIS to save after edit then return 3 Set start press IRIS to set scan start move PTZ to choose the start on the left press IRIS again to confirm and return 4 Set stop press IRIS to set scan...

Страница 14: ...preset point control lever up and down to choose second 1 255 every group can up to set 32 preset point same with other preset points setting press IRIS to save after edit then return Picture 9 shows...

Страница 15: ...ows as 11 Detail operations 1 Time number click IRIS to choose time number move joystick up or down to choose 1 4 number 2 Start time click IRIS to set start time Dome camera can set time in 24 hours...

Страница 16: ...to 90 degree vertically 2 Auto focus mode click IRIS to enter move joystick up or down to choose iris focus close all For example choose iris then lens focus will not change when pan tilt move And th...

Страница 17: ...up or down to choose high or low speed Click IRIS to save and return 2 Digital zoom click IRIS to set digital zoom Move the joystick up or down to open or close digital zoom function 3 Focus limit cl...

Страница 18: ...brighter the image is 6 Digi slow shutter set digital shutter to open or close 7 Day night mode make the camera and IR led change day night mode by force to three modes auto night and day 4 3 WHITE BA...

Страница 19: ...to choose the object needed to cover and be sure the object is in the middle of the monitor again click IRIS to set the size of the area It appears a black rectangular area in the middle At this momen...

Страница 20: ...nal choosing close means not display if choose the seconds it means it will close after the time you choose The others have the same setting as above Global Settings click IRIS can to modify all proje...

Страница 21: ...s IRIS to entry the restore factory setting all the parameter which users set will recover the original one However the system setting pantilt setting alarm setting will not change 7 System restart Pr...

Страница 22: ...etup 1 4 group left right scan setup 1 4 group pattern setup 1 220pcs preset and close shaking the rocker up or down could select one of them close means don t operate anything After setting press IRI...

Страница 23: ...Power cable in short circuit or open circuit Address code protocol baud rate setting is incorrect RS485 length is more than 500m RS485 connection is not good Power is not strong enough Belt is loose o...

Страница 24: ...Before using the camera please read the factory settings of the user manual carefully Power AC200V 50HZ Address1 Protocol PELCO D Baut Rate 2400bps...

Отзывы: