3.6

<WAIT ACTION > setting

Move the cursor to <WAIT ACTION>

click “IRIS+” to enter submenu. The monitor shows as Picture12

<

Picture

operations

1

Wait time

click “IRIS+” to enter and set wait time

move joystick up or down to set wait time from 1 to 

                              255seconds

default time is 5s. for example it is 10s, then dome camera will run action if no 

                              operation in 10s.

2

Run action

click “IRIS+” to run one action. The actions include: cruise number 1-4

left- right soan 

                                  number 1-4

pattern number 1-4

1-220 preset and“close”

Move joystick up or down to 

                                  choose one of them. “close”means don’t run any actions. click “IRIS+” to save and return

3.7

PANTILT SETTING > setting

Move the cursor to <PAN TILT SETTING>

click “IRIS+” to enter submenu. The monitor shows as 

13

Detail operations

1

Auto-flip

click “IRIS+” to enter

move joystick up or down to choose open or close. If set “open”

dome 

                             camera will auto-flip 180 degree horizontally when pan tilt run to 90 degree vertically.

2

Auto focus mode

click “IRIS+” to enter

move joystick up or down to choose iris 

focus

close

all. 

                                               For example choose “iris”, then lens focus will not change when pan tilt move. And 
                                               the lens will auto-focus when operate iris. If choose “all”, then the lens will auto-focus 
                                               when any operations

3

Auto change speed

click “IRIS+” set whether the speed matches lens zoom. The bigger the zoon is,

                                                    the lower the speed is;

4

Manual control speed:

 click “IRIS+” to enter. Move joystick up or down to set 1-128 level. But must set 

                                                       <auto change speed> “close”, then this set works. Click “IRIS+” to save and return.

5

Setting north: 

dome camera can show east

south

west

north

northeast

southeast

northwest

                     

southwest. When the dome camera installation finished, the direction is incorrect, so 

                                      should set right direction of north. Click “IRIS+” to set and move joystick left or right ti 
                                      find the right north. Click “IRIS+” to save and return.

6

Go to zero position: 

click “IRIS+” to make pan tilt go to zero position.

Infrared Intelligent High Speed Dome Camera Operating Manual

15

Picture13<PANTILT>
setting:

  Picture 12<WAIT
 ACTION>setting:

Содержание 8890X Series

Страница 1: ...Infrared High Speed Dome Camera Fourth generation IV Operating manual 8890X series Version V2 0...

Страница 2: ...instant discharge lightning technology which can prevent the lightning under 500W power surge and other kinds of pulse of high voltage to damage the interior of the camera 4 In order to protect the c...

Страница 3: ...Control equipment 2 7 Boot initialization 2 8 Basic operation 3 AUTOMATIC OPERATION SETTING menu operation 3 1 PRESET POINT setting 3 2 LEFT RIGHT SCAN setting 3 3 CRUISE SCAN setting 3 4 PATTERN SCAN...

Страница 4: ...l 3 1 Installation and debugging of Infrared High Speed Dome Camera 1 1 Infrared high speed component name Frontal outline drawing 1 2 Installing hole size figure Whole set size mm Installing hole siz...

Страница 5: ...the left of prevent lighting plate 1 3 7 if the distance between the machine and control equipment over 500 meters connect 485 matching resistor jumpers on the prevent lighting plate to the two pins...

Страница 6: ...to 8 protected areas Can be set to 6 numbers password Date time positon temperature etc Support 4ways output 2ways input colse open optional 40 60 95 no condensation 5 Heating 48 Cooling IP65 400 380...

Страница 7: ...Address protocol baud rate setting After machine installed be sure the ball machine set DIP switch address code protocol baud rate is fully consistent with the control equipment Our High speed Demo c...

Страница 8: ...11100 01000010 01100010 01010010 01110010 01001010 01101010 01011010 01111010 01000110 01100110 01010110 01110110 01001110 01101110 01011110 01111110 01000001 01100001 01010001 01110001 01001001 01101...

Страница 9: ...170 174 178 182 186 190 194 198 202 206 210 214 218 222 226 230 234 238 242 246 250 254 11011001 11111001 11000101 11100101 11010101 11110101 11001101 11101101 11011101 11111101 11000011 11100011 1101...

Страница 10: ...t of the camera s initialization as picture 1 At the mean while the PTZ starts check up down left and right after checking will show system initialization success Then it will standby picture 2 or get...

Страница 11: ...TIC OPERATION SETTING menu operation Attention the manual explanation sequences are based on the practicability of camera function not based on the menu Please choose the sections you need Enter camer...

Страница 12: ...elect the preset number up or down the joystick to select 1 220 preset point number 2 Title Press Iris to enter and edit the title up or down the joysticks to choose numbers letters or characters Left...

Страница 13: ...ers press IRIS to save after edit then return 3 Set start press IRIS to set scan start move PTZ to choose the start on the left press IRIS again to confirm and return 4 Set stop press IRIS to set scan...

Страница 14: ...preset point control lever up and down to choose second 1 255 every group can up to set 32 preset point same with other preset points setting press IRIS to save after edit then return Picture 9 shows...

Страница 15: ...ows as 11 Detail operations 1 Time number click IRIS to choose time number move joystick up or down to choose 1 4 number 2 Start time click IRIS to set start time Dome camera can set time in 24 hours...

Страница 16: ...to 90 degree vertically 2 Auto focus mode click IRIS to enter move joystick up or down to choose iris focus close all For example choose iris then lens focus will not change when pan tilt move And th...

Страница 17: ...up or down to choose high or low speed Click IRIS to save and return 2 Digital zoom click IRIS to set digital zoom Move the joystick up or down to open or close digital zoom function 3 Focus limit cl...

Страница 18: ...brighter the image is 6 Digi slow shutter set digital shutter to open or close 7 Day night mode make the camera and IR led change day night mode by force to three modes auto night and day 4 3 WHITE BA...

Страница 19: ...to choose the object needed to cover and be sure the object is in the middle of the monitor again click IRIS to set the size of the area It appears a black rectangular area in the middle At this momen...

Страница 20: ...nal choosing close means not display if choose the seconds it means it will close after the time you choose The others have the same setting as above Global Settings click IRIS can to modify all proje...

Страница 21: ...s IRIS to entry the restore factory setting all the parameter which users set will recover the original one However the system setting pantilt setting alarm setting will not change 7 System restart Pr...

Страница 22: ...etup 1 4 group left right scan setup 1 4 group pattern setup 1 220pcs preset and close shaking the rocker up or down could select one of them close means don t operate anything After setting press IRI...

Страница 23: ...Power cable in short circuit or open circuit Address code protocol baud rate setting is incorrect RS485 length is more than 500m RS485 connection is not good Power is not strong enough Belt is loose o...

Страница 24: ...Before using the camera please read the factory settings of the user manual carefully Power AC200V 50HZ Address1 Protocol PELCO D Baut Rate 2400bps...

Отзывы: