...........continued
Step
Action
Register R/W Value Description
7
Register access
0x36
W
0x0F —
8
Register access
0x1C
W
0x54 —
9
Register access
0x1C
W
0x42 —
10
Register access
0x34
W
0x00 —
11
Register access
0x3F
W
0x08 —
12
Register access
0x02
W
0x09 Enable PLL_ON state
13
Interrupt event
0x0F
R
0x01 Wait for IRQ_0 (PLL_LOCK)
14
Register access
0x02
W
0x02 Initiate transmission, enter BUSY_TX state
15
Measurement
—
—
—
Perform measurement
16
Register access
0x1C
W
0x00 Disable Continuous Transmission Test Mode
17
Reset
—
—
—
Reset AT86RF212B rev. C
1.
Changing the output power during continuous transmission is not allowed.
ATSAMR30M18A
Continuous Transmission Test Mode Errata
©
2018-2021 Microchip Technology Inc.
and its subsidiaries
Datasheet
DS70005384B-page 61