background image

Page 5

Safety

Industrial Performance Unit

1. 

Safety

System operation assumes knowledge of the operating instructions. The Industrial Performance Unit will also be referred 
to in the following as “controller”.

1.1 

Symbols Used

The following symbols are used in these operating instructions:

Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.

Indicates a situation that may result in property damage if not avoided.

Indicates a user action.

i

Indicates a tip for users.

Measurement

Indicates hardware or a software button/menu.

1.2 

Warnings

Connect the power supply and the display/output device according to the safety regulations for 
electrical equipment. 

 

> Risk of injury 

 

> Damage to or destruction of the sensor
Avoid shocks and impacts to the controller.

 

> Damage to or destruction of the controller

The supply voltage must not exceed the specified limits.

 

> Damage to or destruction of the controller

Lay the power supply cable according to the provisions for electrical equipment. Protect the cables 
against damage.

 

> Failure of the controller

The controller housing may only be opened by authorized persons.

 

> Damage to or destruction of the controller possible

Only plug in or disconnect devices when disconnected from the power supply.
Disconnect the controller from the power supply before cleaning. Only use a damp cloth for clean-
ing. Do not use liquid or aerosol cleaners.
Protect the controller from moisture.
Place the controller on a stable surface during installation. Dropping the controller may damage it.
The openings on the housing provide ventilation. Prevent the controller from overheating. Do not 
cover the openings.
If the controller will not be used again for a while, disconnect it from the power supply.
Never pour liquid into a housing opening.

Содержание Industrial Performance Unit

Страница 1: ...Operating Instructions Industrial Performance Unit...

Страница 2: ...MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon com...

Страница 3: ...ge 10 4 Installation and Assembly 11 4 1 Controller 11 4 2 Electrical Connections 12 4 2 1 Connection Diagram 12 4 2 2 Interfaces 13 4 2 3 Supply Voltage Power 13 4 3 Installation instructions 14 4 4...

Страница 4: ...Industrial Performance Unit...

Страница 5: ...ge to or destruction of the controller The supply voltage must not exceed the specified limits Damage to or destruction of the controller Lay the power supply cable according to the provisions for ele...

Страница 6: ...easuring system is designed for use in industrial environments The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according to the EU Directi...

Страница 7: ...re Industrial Ethernet TCP IP UDP Modbus protocol or the fieldbuses listed below are available for outputting results and controlling the system PROFINET EtherNet IP The flexible industrial grade hard...

Страница 8: ...GB Memory 128 GB SSD Supply voltage 9 36 V DC Power consumption 50 W max 112 W Digital interfaces Gigabit Ethernet GigE Vision GenICam PROFINET EtherNet IP Connection 4 pin supply terminal block 2x R...

Страница 9: ...eaning Off No access to hard drive On Read write access to hard drive LAN 1 2 LEDs Meaning Link LED left Constant orange Gigabit Ethernet connection established Constant green 100 Mbit Ethernet connec...

Страница 10: ...oller 2 mounting adapters for table wall mounting Carefully remove the components of the measuring system from the packaging and ensure that the goods are for warded in such a way that no damage can o...

Страница 11: ...destruction of the controller possible 77 3 03 82 2 3 24 192 7 56 224 8 82 250 9 84 22 87 186 7 32 230 9 01 40 1 57 150 5 91 5 20 14 55 10 39 Dimensions in mm inches Fig 3 Dimensional drawing of SC25...

Страница 12: ...4V scanCONTROL Fig 5 Connecting the scanCONTROL Monitor HDMI cable Controller 3DInspect installed Power supply 24V LAN cable SCR3000X x surfaceCONTROL 3D 35xx surfaceCONTROL 3D 32xx Fig 6 Connecting t...

Страница 13: ...ection for monitor 5 Power supply 4 2 3 Supply Voltage Power The power supply connection is a 4 pin plug connector Pin Designation Comments 9 V 36 V DC nominal value 24 V max power consumption 112 W 0...

Страница 14: ...duct The minimum bending radii are three times the cable diameter and must not be less than this 4 4 Initial Operation The controller may only be connected to peripherals when it does not carry power...

Страница 15: ...ner and may only use this method of access for the aforementioned purposes Any use that extends beyond this in particular any use that endan gers operational safety is prohibited Micro Epsilon is not...

Страница 16: ...asuring system straight away After the supply voltage has been applied The controller starts up The operating system is loaded The user Operator is logged in without having to enter a password 3DInspe...

Страница 17: ...Data view Using this view align the sensor with the target as best as possible Optimize the sensor parameters so that you get an ideal point cloud Set the evaluation parameters according to the measu...

Страница 18: ...s on this in the Running Firmware on the Fieldbus Card section see Chap 7 2 If no error message appears or if a different 3DInspect error message appears after confirming with OK the correct firm ware...

Страница 19: ...ick the OK button The path to the firmware is displayed in the Assigned Module Firmware Files section Click the OK or Apply button A dialog with a prompt to restart the fieldbus card will appear Confi...

Страница 20: ...g parts and in the event of non compliance with the specified maintenance intervals if applicable MICRO EPSILON is exclusively responsible for repairs It is not permitted to make unauthorized structur...

Страница 21: ...ial waste e g residual waste can or the yellow recycling bin and must be disposed of separately This avoids hazards to the environment due to incorrect disposal and ensures prop er recycling of the ol...

Страница 22: ...or the MIC 770 contains details about the CPU You can find the user manual on the D drive of the IPU You can find the operating instructions for the 3DInspect software among the documentation for the...

Страница 23: ...Page 23 Appendix Accessories Industrial Performance Unit 0 205 5 190 8 10 4 4 9 150 5 5 151 5 Fig 11 Dimensions mounting plate for DIN rail mounting...

Страница 24: ...K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide X9751438...

Отзывы: