Page 13
Installation and Assembly
Industrial Performance Unit
4.2.2
Interfaces
All connections for the controller are located on the front.
5
4
3
1
2
Fig. 8 Controller with connections
1
Ethernet socket, 3D sensor
2
Fieldbus
3
HDMI, connection for monitor
4
VGA, connection for monitor
5
Power supply
4.2.3
Supply Voltage (Power)
The power supply connection is a 4-pin plug connector.
Pin/Designation
Comments
-
+
+
-
+
9 V ... 36 V DC
(nominal value 24 V, max.
power consumption 112 W)
-
0 V
Fig. 9 Pin assignment of the power supply connection, view:
Plug on housing side
The operating voltage is protected against polarity reversal. Use only shielded lines or original cables from the accesso-
ries program for the power supply connection or the outputs.