Safety

Industrial Performance Unit

If one of the following instances occurs, have the controller checked by service personnel:

 

-

The power supply cable or plug is damaged.

 

-

Liquid has got into the device.

 

-

The controller was exposed to moisture.

 

-

The controller is malfunctioning or not working as per the operating instructions.

 

-

The controller was dropped and damaged.

 

-

The controller has obvious signs of breakage.

Store the device within the storage temperature limits. The equipment should be stored in a con-
trolled environment.
CAUTION: Batteries may explode if they are used incorrectly. Only replace with the same or equiv-
alent types, as recommended by the manufacturer. Dispose of used batteries according to the 
instructions of the manufacturer.
The controller should only be installed in an area with restricted access.
Store or save the operating instructions in a secure location. 

1.3 

Notes on CE Marking

The following apply for the Industrial Performance Unit: 

 

-

EU Directive 2014/30/EU

 

-

EU Directive 2011/65/EU

Products which carry the CE mark satisfy the requirements of the EU directives cited and the relevant applicable harmo-
nized European standards (EN). The measuring system is designed for use in industrial environments. 
The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according 
to the EU Directives.

1.4 

Notes on FCC Marking

The device meets the requirements of section 15 of the FCC rules.

1.5 

Intended Use

 

-

The Industrial Performance Unit is designed for use in industrial environments. It is used as a high-performance solu-
tion for 3D measuring tasks, with the connection to master control units being possible via conventional fieldbuses.

 

-

The controller must only be operated within the limits specified in the technical data, see 

Chap. 2.4

.

 

-

The controller must be used in such a way that no persons are endangered or machines and other material goods are 
damaged in the event of malfunction or total failure of the controller. 

 

-

Take additional precautions for safety and damage prevention in case of safety-related applications.

1.6 

Proper Environment

 

-

Protection class: 

IP40

The IP40 protection class is a specification that is limited to protection from dust and water.  Oil, steam and emulsion 
effects are not included in this protection class and must be evaluated separately.

 

-

Temperature range  

 

ƒ

Operation: 

0 ... +50 °C 

1

 

 

ƒ

Storage: 

-40 ... +85 °C 

 

-

Humidity: 

20 ... 95% (non-condensing)

 

-

Ambient pressure:  Atmospheric pressure

1) Maximum permissible operating temperature at 0.7 m/s air flow

Содержание Industrial Performance Unit

Страница 1: ...Operating Instructions Industrial Performance Unit...

Страница 2: ...MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon com...

Страница 3: ...ge 10 4 Installation and Assembly 11 4 1 Controller 11 4 2 Electrical Connections 12 4 2 1 Connection Diagram 12 4 2 2 Interfaces 13 4 2 3 Supply Voltage Power 13 4 3 Installation instructions 14 4 4...

Страница 4: ...Industrial Performance Unit...

Страница 5: ...ge to or destruction of the controller The supply voltage must not exceed the specified limits Damage to or destruction of the controller Lay the power supply cable according to the provisions for ele...

Страница 6: ...easuring system is designed for use in industrial environments The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according to the EU Directi...

Страница 7: ...re Industrial Ethernet TCP IP UDP Modbus protocol or the fieldbuses listed below are available for outputting results and controlling the system PROFINET EtherNet IP The flexible industrial grade hard...

Страница 8: ...GB Memory 128 GB SSD Supply voltage 9 36 V DC Power consumption 50 W max 112 W Digital interfaces Gigabit Ethernet GigE Vision GenICam PROFINET EtherNet IP Connection 4 pin supply terminal block 2x R...

Страница 9: ...eaning Off No access to hard drive On Read write access to hard drive LAN 1 2 LEDs Meaning Link LED left Constant orange Gigabit Ethernet connection established Constant green 100 Mbit Ethernet connec...

Страница 10: ...oller 2 mounting adapters for table wall mounting Carefully remove the components of the measuring system from the packaging and ensure that the goods are for warded in such a way that no damage can o...

Страница 11: ...destruction of the controller possible 77 3 03 82 2 3 24 192 7 56 224 8 82 250 9 84 22 87 186 7 32 230 9 01 40 1 57 150 5 91 5 20 14 55 10 39 Dimensions in mm inches Fig 3 Dimensional drawing of SC25...

Страница 12: ...4V scanCONTROL Fig 5 Connecting the scanCONTROL Monitor HDMI cable Controller 3DInspect installed Power supply 24V LAN cable SCR3000X x surfaceCONTROL 3D 35xx surfaceCONTROL 3D 32xx Fig 6 Connecting t...

Страница 13: ...ection for monitor 5 Power supply 4 2 3 Supply Voltage Power The power supply connection is a 4 pin plug connector Pin Designation Comments 9 V 36 V DC nominal value 24 V max power consumption 112 W 0...

Страница 14: ...duct The minimum bending radii are three times the cable diameter and must not be less than this 4 4 Initial Operation The controller may only be connected to peripherals when it does not carry power...

Страница 15: ...ner and may only use this method of access for the aforementioned purposes Any use that extends beyond this in particular any use that endan gers operational safety is prohibited Micro Epsilon is not...

Страница 16: ...asuring system straight away After the supply voltage has been applied The controller starts up The operating system is loaded The user Operator is logged in without having to enter a password 3DInspe...

Страница 17: ...Data view Using this view align the sensor with the target as best as possible Optimize the sensor parameters so that you get an ideal point cloud Set the evaluation parameters according to the measu...

Страница 18: ...s on this in the Running Firmware on the Fieldbus Card section see Chap 7 2 If no error message appears or if a different 3DInspect error message appears after confirming with OK the correct firm ware...

Страница 19: ...ick the OK button The path to the firmware is displayed in the Assigned Module Firmware Files section Click the OK or Apply button A dialog with a prompt to restart the fieldbus card will appear Confi...

Страница 20: ...g parts and in the event of non compliance with the specified maintenance intervals if applicable MICRO EPSILON is exclusively responsible for repairs It is not permitted to make unauthorized structur...

Страница 21: ...ial waste e g residual waste can or the yellow recycling bin and must be disposed of separately This avoids hazards to the environment due to incorrect disposal and ensures prop er recycling of the ol...

Страница 22: ...or the MIC 770 contains details about the CPU You can find the user manual on the D drive of the IPU You can find the operating instructions for the 3DInspect software among the documentation for the...

Страница 23: ...Page 23 Appendix Accessories Industrial Performance Unit 0 205 5 190 8 10 4 4 9 150 5 5 151 5 Fig 11 Dimensions mounting plate for DIN rail mounting...

Страница 24: ...K nigbacher Str 15 94496 Ortenburg Deutschland Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide X9751438...

Отзывы: