Page 18
Setting Up Fieldbus Operation
Industrial Performance Unit
7.
Setting Up Fieldbus Operation
7.1
General
The controller offers the possibility of control and transmission of measured values computed in 3DInspect via fieldbus.
For this purpose, the respective fieldbus must be set in the
Output
tab in 3DInspect.
If the error message
Input/Output: Error fieldbus startup
appears after confirming with
OK
, the correct
firmware must still be installed on the fieldbus card. You can find details on this in the “Running Firmware on the Fieldbus
Card” section, see
.
If no error message appears or if a different 3DInspect error message appears after confirming with
OK
, the correct firm-
ware is already installed on the fieldbus card. The steps from the following chapter no longer have to be carried out.
7.2
Running Firmware on the Fieldbus Card
The following steps must be carried out in sequential order for the correct firmware to be stored for the fieldbus card:
Exit 3DInspect if you haven’t already.
Open the control panel. To do this, click on the Windows icon and click on
Control Panel
.
Open
cifX Setup
. This step requires authentication with the created administrator account.