Ethernet Interface
combiSENSOR 64x0
6.4.20
Change Language for the Web Interface (LNG)
Changes the language of the web interface.
Command
$LNGn<CR>
Response
$LNGnOK<CRLF>
Index
0 = System
1 = English
2 = German
6.4.21
Default Messages
- Unknown command: (ECHO) + $UNKNOWN COMMAND<CRLF>
- Wrong parameter after command: (ECHO) + $WRONG PARAMETER<CRLF>
- Timeout (approximately 15 s after last input) (ECHO) + $TIMEOUT<CRLF>
- Wrong password: $WRONG PASSWORD<CRLF>
6.5
Operation Using Ethernet
Dynamic web pages are generated in the controller which contain the current settings of the controller and
the peripherals. Operation is only possible while there is an Ethernet connection to the controller.
6.5.1
Requirements
You need a web browser with HTML5 support (e.g. Mozilla Firefox
3.5 or Internet Explorer
10) on a PC
with a network connection. To support a basic first commissioning of the controller, the controller is set to a
direct connection.
If you have configured your browser to access the internet via a proxy server, in the browser settings you will
need to add the IP address of the controller to the list of addresses which should not be routed through the
proxy server.
“Javascript” must be enabled in the browser so that measurement results can be displayed graphically.