Page 42
Ethernet Interface
combiSENSOR 64x0
6.4.12
Change between Ethernet and EtherCAT (IFC = Interface)
Command switches between Ethernet and EtherCAT interface. Effective only, if the switch
Ethernet/
EtherCAT
is in the position
ECAT/Auto
. Otherwise always the Ethernet interface is active. The new inter-
face is activated after a restart of the controller.
IFC
Command
$IFCm<CR> Example: $IFC1<CR>
Response
$IFCmOK<CRLF>
Index
m = 0: Ethernet
m = 1: EtherCAT
Request
Command
$IFC?
Response
$IFC?mOK<CRLF>
6.4.13
Query Data Port (GDP)
Queries the port number of the data port.
Command
$GDP<CR>
Response
$GDP<Port number>OK<CRLF>
Example: $GDP10001OK<CRLF>
6.4.14
Set Data Port (SDP)
Sets the port number of the data port. Range: 1024 ...65535.
Command
$SDP<Portnumber><CR> Example: $SDP10001OK<CR>
Response
$SDP<Portnumber>OK<CRLF>