Page 14
Functional Principle, Technical Data
combiSENSOR 64x0
2.2.2
Sensor Cable
The sensor and controller are connected by a special, double screened, 1 m (3 ft) long sensor cable KC1.
Do not shorten or lengthen these special sensor cable. Do not crush the sensor cable. Do not modify
the sensor cable. This leads to a loss of functionality or of the specified technical data.
Install the sensor cable in a protected area.
A damaged cable can not be repaired. The sensor cable is not suitable for cable carriers. Minimum bending
radius: 20 mm (once), 80 mm (permanently).
i
Switch off the power supply of the controller, when plugging and removing connectors.
2.2.3
KSS64x0 Controller
The controller contains an oscillator and
a signal conditioning electronics for the
sensor. The capacitive and eddy current
part of the sensor are synchronized with
each other.
Power supply, Trigger In
Sensor
Ethernet / EtherCAT
Eddy and capa signal
differential and temperature signal
Fig. 4 Controller measuring system