Overview of Mechanical Components
thicknessCONTROL MTS 8202.LLT / 4350127.347
3.6
Human-Machine Interface
The components shown in the following sections are necessary for operating the system.
1 2
3 4
5
1 On/Off Switch
2 PC active / LED is green
3 Segment stop
4 Reset segment stop
5 Maintenance unit
Fig. 16 Operating elements at the measuring system/control cabinet
3.6.1 Signal Lamp
To visualize the operating states over long distances, the system features a signal
lamp(1), which is mounted on the control cabinet of the measuring system.
The signal lamp is in the control cabinet of the measuring system
.
1
1 Signal Lamp
Fig. 17 Signal Lamp
Initializing: flashing green
Ready: constant green
Measuring: constant yellow
Calibrating: flashing yellow
Outside tolerance: red
Constant error: flashing red
3.6.2 Emergency Stop
The measuring system does not have its own EMERGENCY stop button. The measuring
system uses the emergency stop signal from the production line. If an emergency STOP
signal is detected, the measuring system will terminate the thickness measurement. If the
emergency stop is canceled by production control, the sensor system travels back to the
home position.
Содержание 4350127.347
Страница 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Страница 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Страница 35: ...Page 35 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347 Fig 39 System parameter...
Страница 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Страница 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Страница 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...