4.3 Electrical
The 115±5VAC supply lines are connected into the Green Connector block located to the left hand side of the control
unit. Words clearly indicate its correct wiring. The ground wire is also connected into the Green Connector block.
The control board settings have been pre-set prior to shipment. It will be necessary for the door operator to be
functional while adjustments and settings are made. Please follow these instruction for a successful installation.
A black push actuator
button indicated by ‘TEST/LEARN’ is mounted to the lower left corner of the Visual display to
ease in the adjustment process.
Once the unit is powered up, and before the arm is installed. Push
the ‘TEST/LEARN’ button in order to check the
spline drive shaft rotates in the correct direction.
Keep all wires away from moving parts and sharp edges that may cut into the outer casing of the wires.
Installation of any extra wiring for controls or accessories into the header unit shall be secured and away from any
moving parts.
If the motor is not plugged into the circuit board, there is no resistance against the spring when manually opening the
door. The door or arm will close very quickly if opened.
If an electrical access hole is added or knocked-out of the end plates, code approved electrical transfers must be
used. Hole cannot be knocked out and unfilled.
ON
4.4 Required Tools for installation:
•
Allen Wrench Set
•
Power Drill and Drill Bits
•
Level
•
Tape Measure
•
Wire Stripper
•
Screwdrivers: Flat, Philip, 5/16” Hex. Nut
•
Additional Fasteners Depending Surface
•
Shims
•
Hand Saw/ Power Saw
4.5 Suggested Fasteners for Frame
•
#14 x 2-
3/4” (70mm) long sheet metal screws for wood.
4.6 Suggested Fasteners for Door
•
#12, #14, Wood screws, Sheet Metal screws, Self-tapping screws of varying lengths depending on
applications.
•
Typically, doors are hung on hinges 5” (127mm) max. Width or 3/4” (19mm) offset pivots.