Smart Swing 3
®
Installation Manual
SMART SWING 3 ®
Page 27 of 36
HOLD ON MANUAL OPEN
Door held open when pushed by hand. Not
active with push & go.
(2 options)
a = No
b = 5 steps (1-5 sec)
3
ELECTRONIC DOOR STOP
Setting stop position by encoder
(2 options)
Y = Yes
N = No
Yes
E-LOCK
Strike or Electromagnetic Lock
(2 options)
Y = Yes
N = No
No
E-LOCK DELAY
Time before E-Lock will release
(18 steps : 0.2 sec to 2.0
sec)
0.2 sec = minimum
2.0 sec = maximum
1.0
LATCH POSITION
Position at which final section of closing
begins
(15 steps : 2% to 30%)
2% = minimum
30% = maximum
10
BACK CHECK POSITION
Position at which final section of opening
begins
(15 steps : 70% - 98%)
70% = maximum
98% = minimum
90
PUSH & GO
(2 options)
Y = Yes
N = No
No
PUSH & GO TIME
Time door is pushed open before
activation
(30 steps)
1sec = minimum
30sec = maximum
3
POWER CLOSE
Power assisted closing with spring
(2 options)
Y=Yes
N = No
No
REVERSE ON OBSTRUCTION
(2 options)
Y=Yes
N = No
No
OVERLAP
(2 options)
Y=Yes
N = No
No
FACTORY RESET
(2 options)
Y=Yes
N = No
No
LIGHT ON TIME
Time backlight remains on
(30 steps)
1sec = minimum
30sec = maximum
1