Smart Swing 3
®
Installation Manual
SMART SWING 3 ®
Page 33 of 36
J3.3
ACTIVATION
2
(Input) This signal (to COM) will activate the operato
r. (If ‘AUTO’ signal (J2.3) is to COM with no
current fault present and door is not fully closed.
J3.4
SAFETY 1
(Input) When the door is fully closed, this signal (to COM) will prevent an activation.
When the door is fully opened, this signal (to COM) will prevent the door from entering the closing
cycle.
J3.5
SAFETY2
(Input) When the door is fully closed, this signal (to COM) will prevent and activation.
When safety signal clears, pending activation will activate the operator. During the opening cycle,
the door will go to safety (Hold) speed. (When the signal is to COM)
When the door is fully opened, this signal (to COM) will prevent the door from entering the closing
cycle.
J3.6
PC CANCEL
(Input) This signal (to COM) will prevent or cancel power close
J3.7
DOOR
CLOSED
(Output) This signal is tied to COM when door is fully closed. Door must be set up (Learning
Completed)
J3.8
IN1
(input) Not used
J3.9
GND
Ground reference for signals and power
J3.10
OUT1
(Output) Not used
J3.11
OUT2
(Output) Not used
J3.12
OUT3
(Output) Not used
J4 - Connector Description: Sensor power and electric lock outputs
PIN
Definition
J4.1
(Output) +24VDC (500Ma max)
J4.2
(Output) +12VDC (500Ma max)
J4.3
(GND) Ground reference for signals and power
J4.4
(Output) Electric lock relay N.C. (Normally Closed)
J4.5
(Output) Electric lock relay N.O. (Normally Open)
J4.6
(COM) Electric lock relay common
J5 - Connector Description: Motor output (Isolated from power input)
PIN
Definition
J5.1
Motor Positive
J5.2
Motor Negative
J5.3
AC Ground
J6 - Connector Description: Motor encoder
PIN
Definition
J6.1
(Output) +5V DC
J6.2
(Input) Encoder Signal B
J6.3
(Input) Encoder Signal A
J6.4
COM (Ground)
J7 - Connector Description: ISP/SYNC/Communication
PIN
Definition