Smart Swing 3
®
Installation Manual
SMART SWING 3 ®
Page 26 of 36
8.8. Electromagnetic Lock
9.0 Basic Setting Table
Line Voltage
Model
Software version
90 - 250VAC 5060Hz
CU SMART SWING 3
MSW01 VX.XX
FUNCTION DESCRIPTION
SETTING
VALUE
DEFAULT
OPENING SPEED
Door opening speed from full closed to
back check position
(5 to 20)
5 = slowest
20 = fastest
10
BACK CHECK SPEED
Door speed at final section of opening
(1 to 5)
1 = slowest
5 = fastest
5
SAFETY SPEED
Slow speed (crawl) or stop (hold) when
safety1 is active
(2 steps)
HOLD / CRAWL
HOLD
CLOSING SPEED
Door closing speed from full open to latch
position
(1 to 15)
1 = slowest
15 = fastest
5
LATCH SPEED
Door speed at final section of closing
(1 to 5)
1 = slowest
5 = fastest
2
CURRENT LIMIT
Obstruction detection
(1 to 20)
1= more sensititve
20 = less sensitive
10
ACTIVATION TIME
Time begins at activation signal ON.
(1-60 steps : 1 to 60sec)
1 = minimum
60 = maximum
5