MONGOOSE PRO Shale Shaker
18
Field Installation and Operation Manual 9092F02001AENG (D)
18
10.1.3.2
Connecting ATEX/IECEx Panel
The ATEX/IECEx rated panel (Refer to Figure 16) is configured as specified below:
Figure 16. ATEX/IECEx Motor Control Panel
1.
Power Indicator Light
2.
Thermal Overload Indicator Light
3.
I/O Power
4.
Capacity Operation Indicator Light
5.
Red STOP Button
6.
Emergency Stop button
7.
Normal / Capacity Selector Switch
8.
Start Motors Indicator Light
9.
Green START Button
10.
Normal Operation Indicator Light
The ATEX/IECEx rated control panel is equipped with a white power indicator light. When illuminated, the unit
is powered on. It is also equipped with operation mode indicator lights. When the “Normal” light is illuminated,
the unit is operating in “Progressive Elliptical” mode. When the “Capacity” light is illuminated, the unit is
operating in “Balanced Elliptical” mode.
The ATEX/IECEx rated control panel is equipped with a yellow thermal overload indicator light. It illuminates
when the motor temperature exceeds safe operating levels.
ATEX/IECEx rated control panels have a large I/O power lockout switch on the front of the panel. The unit is
powered when the switch is in the “I” position. Power to the unit is shut off when the switch is in the “O”
position.