M
‑
I SWACO
MONGOOSE PRO Shale Shaker
9
Field Installation and Operation Manual 9092F02001AENG (D)
9
6.2
Performance
Rated Motor Output ------------------------- 2.49hp [1.86kW]
Output Force ---------------------------------- 6.5 Gs (Normal Mode) & 7.5Gs (Capacity Mode)
Filtering Area --------------------------------- 30ft
2
[2.73m
2
] per shaker
Operating Temperature --------------------- 86°F [30°C]
6.2.1
Noise Data
Normal Operating Mode ------------------- 74.3 dBA
Capacity Operating Mode ------------------ 75.2 dBA
6.3
Consumption Requirements
Table 1. Electrical Consumption Data
DESCRIPTION
VOLTAGE
INPUT POWER
OUTPUT POWER
FREQUENCY
SHALE SHAKER
2-MOTOR
DRIVE
220-240V
2.25KW
2.5HP [1.86KW]
60HZ
380-415V
2.25KW
2.5HP [1.86KW]
50HZ
440-480V
2.25KW
2.5HP [1.86KW]
60HZ
575-600V
2.25KW
2.5HP [1.86KW]
60HZ
7.
HANDLING AND TRANSPORTING
The MONGOOSE PRO Shale Shaker should always be transported to rig locations on a flatbed truck. Make sure
the unit is properly secured prior to departure and the shipping brackets are installed.
WARNING
NEVER ATTEMPT TO MOVE OR LIFT THE MONGOOSE PRO SHALE SHAKER
WITHOUT THE SHIPPING BRACKETS SECURED TO THE EQUIPMENT! REFER TO
PARAGRAPH 10.2 FOR INFORMATION CONCERNING SHALE SHAKER SHIPPING
BRACKETS.
WARNING
FAILURE TO SECURELY TIE DOWN EQUIPMENT TO TRUCK COULD CAUSE THE
UNIT TO MOVE OR FALL DURING TRANSPORT, RESULTING IN PERSONAL INJURY.
WARNING
USING ANY LIFTING OR HOISTING DEVICE AND ACCESSORY ITEM THAT IS NOT
RATED TO SUPPORT THE UNIT WEIGHT CAN CAUSE PERSONAL INJURY OR DEATH
FROM THE UNIT FALLING OR BEING UN-CONTROLLED WHEN HANDLING.