65
STRATA1
3 8 & 3 8 / 4 6 C O M B I
22.0 screen display/diagnosis of faults (contd)
Reset Key
There is a fault with the reset button.
29, 31, 34
Eeprom
There is a fault in the EEPROM in the control.
29
Intern Fault
There is an internal fault in the control panel.
Test Fault
There is a fault with the test button.
29, 31
22.1 (possible) causes of fault
& corrective action
Cause No.
Reason/Action
1.
Operational function No. not set correctly / Check and correct settings. See tables 11,
12, 13.
2.
Unsound electrical connections to flue limit stat / Check and correct.
3.
Sensor not correctly connected or sensor defective/Check connections and or
replace sensor.
4.
Short circuit in wiring / Check and rectify.
5.
Short circuit in wiring to sensor / Check and rectify.
6.
Boiler pump not rotating (seized or defective)/Free seized shaft or if defective
replace pump.
7.
System lacks water / Investigate, refill and vent.
8.
Connections to heat exchanger limit stat unsound /check & rectify.
9.
Unsound electrical connection to fan / Check integrity of fan connection plug.
10.
Fan blades heavily contaminated / Clean fan.
11.
Fan is defective / Replace fan.
12 .
There is no gas supply available / Investigate, restore gas supply.
13.
Low gas pressure / Investigate and rectify.
14.
Fuse defective / Check fuses and replace as necessary.
15.
Gas valve min output setting is incorrect / Check and adjust min output CO
2
%.
16.
Oxidation on burner mounting screws / Loosen and retighten screws.
17.
Poor ignition lead connection to electrode or damp connection or lead damaged and
shorting to earth / Check and rectify.