STRATA1
3 8 & 3 8 / 4 6 C O M B I
7. set MV timer
This is a user function and at this option, the on/off times for an under floor coil circuit (that is
controlled by an MR03 mixing valve regulation control box from MHS Boilers) may be set.
To set operational times for under floor circuit operation, follow the procedure as described in 19.4.5
a to l. Default on 0.600 – off 23.00.
8. setback
This is a user function and sets the reduction in room temperature for overnight operation. This is a
reduction in temperature from that which is set in 19.4.3 – Day temperature. Default value 5°C.
To programme set back temperature:-
a) With “SETBACK” displayed on the screen press “Menu”.
b) “___°C” will flash on the screen, press “+” or “-“ to raise or lower the value to the required setting
and then press “Menu” to confirm the entry.
9. holiday
This is a user function and allows up to 255 days of holiday period to be programmed.
During this period the heating will operate (if in winter mode) at “setback” temperature see 19.4.8 and
the domestic hot water will be maintained at a minimum of 20°C.
After the number of “holiday” days has expired, the unit will revert back to the normal operation.
NOTE: If the heating circuit is being controlled by an RE2132 modulating room unit, then this piece of
control equipment should also be “holiday” programmed. See instructions supplied with the RE2132 unit.
Default setting 0 days.
To programme a holiday period:-
a) With “holiday” displayed on the screen press “Menu”.
b) “___days” will flash on the screen press “+” or “-“ to input the required number of days in the holiday
period and then press “Menu” to confirm the entry.
The holiday period should be programmed on the day that the holiday begins.
10. installer
This function should not be accessed by the user and is code protected. For Installer programming
instructions see 19.6.
11. back
This is the end of the menu. Press “Menu” to exit.
19.5 setting the control panel (contd)
19.6 installer programming
of control panel
A number of operational options are available to the installer. These can only be accessed by means of
a pass code. If the correct code is entered at 19.4.10 then the following parameters may be set, see 19.5.2.
(For installer code no see bottom right hand corner of page).
1. to enter installer programming menu:-
a) With “INSTALLER>” displayed on the screen press “Menu”.
b) Code: 0 will flash on the screen press “+” or “-“ to input the installer code and then press “Menu” to
confirm the entry and access the installer menu.
2. installer programme menu
Scroll through menu using “+” or “-“ buttons. The current setting for any parameter will be displayed
under the particular parameter title.
✁
Installer
Code
= 21