57
STRATA1
3 8 & 3 8 / 4 6 C O M B I
19.6 installer programming (contd)
System Type
Room Controls Type
CH Flow
Function
Temperature
Number
Outside air temperature controlled,
With RE2132 modulating room unit
Max 55°C
1
without a secondary underfloor
Max 70°C
2
mixing circuit
Max 85°C
3
With room thermostat/volt free switch
Max 55°C
4
Max 70°C
5
Max 85°C
6
Without room controls
Max 55°C
7
Max 70°C
8
Max 85°C
9
Outside air temperature controlled,
With 2Nr RE2132 room units
Primary 70°C
10
with a secondary underfloor
Primary 85°C
11
mixing circuit and MR03 controller
With 1Nr RE2132 modulating room unit
Primary 70°C
12
Primary 85°C
13
With room thermostat/volt free switch
Primary 70°C
14
Primary 85°C
15
Without room controls
Primary 70°C
16
Primary 85°C
17
No outside air temperature control,
With RE2132 modulating room unit
Max 55°C
18
and without secondary underfloor
Max 70°C
19
mixing circuit
Max 85°C
20
With room thermostat/volt free switch
Max 55°C
21
Max 70°C
22
Max 85°C
23
No outside air temperature control,
With 2Nr RE2132 modulating room units
Primary 70°C
24
and with secondary Underfloor
Primary 85°C
25
mixing circuit and MR03 controller
With 1Nr RE2132 modulating room unit
Primary 70°C
26
Primary 85°C
27
With room thermostat/volt free switch
Primary 70°C
28
Primary 85°C
29
Fixed constant flow temperature with no outside air temperature control and without room controls.
Without secondary underfloor mixing circuit
Max 55°C
30
Max 70°C
31
Max 85°C
32
With secondary underfloor mixing circuit
Primary 70°C
33
and MR03 controller
Primary 85°C
34
Table 11
Valid for Combi boilers and standard boilers where primary hot water control is via a 3 way
divertor valve.
Table 12
Valid for combi and standard Strata 1-38 boilers. Multiple boiler installation with boilers controlled by
a cascade manager.
System Type
Function
Number
KKM2 Modulating Kaskade Manager
35
Analog cascade manager with signal 0-3v or 0-10v*
36
* Boilers must be fitted with optional extra 0-10v interface