21
STRATA1
3 8 & 3 8 / 4 6 C O M B I
minimum dimensions of flue terminal positions
See fig 19.
Dimension
Terminal
Balanced flue
Non room
position
room sealed
sealed
A
Directly below an opening, air
300mm
300mm
brick, windows etc.
Not recommended.
B
Below gutters, soil pipes or
75mm
75mm
drain pipes.
C
Below eaves.
200mm
200mm
D
Below balconies or car port
200mm
200mm
roof. Not recommended.
E
From a vertical drain pipe or
150mm
150mm
soil pipe.
F
From an internal or
300mm
200mm
external corner.
G
Above ground, intersecting
300mm
300mm
roof or balcony level.
H
From a surface facing
2000mm
2000mm
the terminal.
I
From a terminal facing
2000mm
2000mm
the terminal.
J
From an opening in the car port
1200mm
1200mm
(e.g. door, window) into dwelling.
K
Vertically from a terminal on the
1500mm
1500mm
same wall.
L
Horizontally from a terminal on
300mm
300mm
the same wall.
M
From a vertical structure on
500mm
N/A
the roof.
N
Above intersection with roof.
500mm
150mm
P
Directly above an opening, air brick,
300mm
300mm
window etc.
Q
Horizontally to an opening, air brick,
500mm
500mm
window etc.
15.0 flue terminal positions (contd)
but installation
not recommended.
but installation
not recommended.
but installation
not recommended.
but installation
not recommended.
but installation
not recommended.
but installation
not recommended.