20
EXTERNAL CHARGING LED
The external charging LED (super yellow) will be on when the wall mount charger or vehicle
mount charger charges the transmitter battery.
LOCATE POWER LED
The locater power LED (super green) will flash when the Mode Switch is set to the following
modes: Induce, Line Locate Only or Fault & Line Locate. The flashing LED also indicates
the transmitter is “ON”.
LCD DISPLAY
The bar graph indicates two types of information:
Battery status and the total fault resistance measured on the conductor. The LCD is on only
in the Fault & Line Locate mode.
SFL CONDUCTIVE ATTACHMENT OUTPUT JACK
Jacks for connecting red and black lead cables to the Transmitter. Maintain the convention of
connecting the black cable to the grounding spike and the black lead to the back input.
Connect the red cable to the sheath under test, and the red lead to the red input. Failure to do
so will cause the A-frame to point toward the ground spike and away from the fault.
HIGH VOLTAGE LED
The high voltage LED (super RED) will flash when the Mode Switch is set to the Fault &
Line Locate Mode. The flashing red LED is an indication of high voltage present at the
“FAULT OUTPUT” jacks. Do not touch these jacks, electrical shock will result!
MODE SWITCH
Turns the transmitter ON/OFF and selects the three locating modes.
OUTPUT CLAMP JACK
Insert the MetroClamp or standard conductive attachment phone plug into this jack only.
CHARGE JACK
(Optional Feature)
Two types of battery chargers can be used to charge the transmitter battery:
- Wall
mount
charger
-
Vehicle mount 12-volt DC power lead