Pinpoint the Fault
1
Keep the A-Frame parallel to the target cable.
2
Insert the A-Frame every 10-20 ft. Follow the arrow.
3
When the arrow changes direction, backtrack. Look at the Active number and
compare it to the Reference number. If the Active number is similar to the
Reference number, you have located the main fault.
4
Insert the A-Frame every two feet until the arrow changes direction again.
5
Move the A-Frame across the cable until a slight movement causes the arrow
to change direction. The fault is located at the center of the A-Frame.
6
Check entire cable for multiple faults. If more faults are present, check the
Active number at each fault site and compare it to the Reference number. The
higher the Active number the larger the fault.
If you have difficulty with your Metrotech 480B/SFL2Dx Sheath Fault Locator, check the
manual for additional tips. If it still doesn’t work, call us at 1-800-446-3392.