9
2
Monitor bar-graph LCD display for arrow direction. If the arrow points
away from the ground rod, there is a fault.
3
If the arrow points towards the ground rod, there is no fault, and
grounds and connections need to be rechecked
4
A Reference number will be displayed at turn on and will stay fixed until
A-frame is turned off. The Reference number indicates
the potential gradient associated with the fault at the synchronization
location.
5 The Active number will be displayed at the same time as the Reference
number, but it will change when the A-frame spikes are pulled out. The
Active number will decrease when you move away from the synchronization
location and will increase as you get closer to the fault on the cable. The
Active and Reference numbers are available to help you differentiate major
faults from minor faults.
See Figure 3-6.