8.3.3
Connection: PROFIBUS [X401] and [X402]
The PROFIBUS interface at the servo drive DIS-2 310/2 FB FS STO is configured according to
EN 50170 as a 5-pole M12 plug, B-coded at the technology module as plug and socket.
Configuration on the device:
[X401] M12 flush-type plug, 5-pin type, B-coded
[X402] M12 flush-type plug, 5-pin type, B-coded
Counterplug:
Assembled M12 bus cable, for example made by Phoenix,
one end female connector straight, shielded M12-B-coded, 2-
pin type, other end male connector straight, shielded M12-B-
coded, 2-pin type, pre-fabricated lengths, order name:
SAC-5P-MS/xxx-920/FS SCO
xxx defines the length in [m]. The following lengths are
available:
xxx = 0.3 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 / 15.0
Length in metres
Order number
0,3
1518106
0,5
1518119
1,0
1518122
2,0
1518135
Length in metres
Order number
5
1518148
10
1518151
15
1518164
Terminating resistor PROFIBUS M12:
1507803
Figure 34:
Position and connection PROFIBUS interface
Table 42:
Pin assignment [X401] and [X402]
Pin No. Denomination
Values
Specification
1
+5V
+5V
2
A-line
green
Signal A according to the PROFIBUS specification
3
0V
0 V
Internally connected with the common reference
potential for the logic system
4
B-line
red
Signal B according to the PROFIBUS specification
5
Shield
PE
Contact for cable shield, in the DIS-2 310/2 FB FS
STO connected with the housing