![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027040.webp)
Technical data
Page 40
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
4.5
Communication interfaces
4.5.1
RS232 [X5]
Table 15:
Technical data: RS232 [X5]
Parameter
Values
RS232
as per RS232 specification, 9600 Baud to 115,2 kBaud
4.5.2
I/O interface [X1]
Table 16:
Technical data: Digital inputs and outputs [X1]
Parameter
Values
Signal level
24V (14V … 30V) active high
DIN0
DIN1
DIN2
DIN3
Bit 0 \
Bit 1, \ Target selection for positioning
Bit 2, / 16 targets selectable from target table
Bit 3 /
DIN4 (usable as incremental
input A-signal)
Bit 4 \
\ Target selection for positioning
/ 4 target groups with separate positioning parameter
Bit 5 / selectable (e.g. speed, acceleration)
DIN5 (usable as incremental
input B-signal)
DIN6 (usable as incremental
input N-signal)
Control signal start positioning
DIN7
End switch input 0
DIN8
End switch input 1
DIN9
Servo drive enable at high signal,
acknowledge error with falling edge
Logic outputs general
24V (8V... 30V) active high, short circuit rated to GND
DOUT0
Operational state / Ready
24 V, max. 20 mA
DOUT1
Freely configurable, usable as
Encoder output A-signal
24 V, max. 20 mA
DOUT2
Freely configurable, usable as
Encoder output B-Signal
24 V, max. 20 mA
DOUT3 (
on [X3]
)
Holding brake
24 V, max. 700 mA