Functional safety technology
Page 72
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
Figure 15:
General "Status" window and "Safety module
– Status" window with the state
"Safe state reached"
6.6.4
"Safety module
– Parameters" window
In order to use the DIS-2 FB FS STO servo drive with the integrated STO safety function, the
Safety
module
– Parameters
window has been added to the DSC parameterisation software.
This window can be opened via the menu
Parameters
– Functional safety – Parameters
and it is
used to parameterise the discrepancy time.
This value is preset to 100 ms and should be fine for the usual applications. If necessary, the
discrepancy time (see
section 6.2.3.1
) between STO1 and STO2 can be prolonged to up to 1 s.
Figure 16:
"Safety module
– Parameters" window