5 Electrical installation
5.7
Connector BL 4100-D: motor [X6]
On BL 4100-D type devices, the motor is connected via a Intercontec connector. The
motor is connected to the terminals U,V,W. An analogue motor temperature sensor can be
connected to the terminals MT+ and MT- if it is routed together with the motor phases in
one cable. Alternatively, it can be connected via the encoder cable to [X2] (section 5.10
Connector BL 4000-D: resolvers and encoder [X2]
on page 48). A holding brake of the
motor can be connected to terminals BR+ and BR-. If a motor with a HIPERFACE DSL
®
encoder is used, this encoder is also connected via [X6].
Configuration on the device [X6]
Intercontec 615/915 ytec Double-Receptacles angled rotatable
EEDA107NN00000002000 with Inserts 60.251.11 and 60.252.11
Mating connector [X6]
Intercontec 615/915 ytec Double-Receptacles angled rotatable
ESTA201MR01320500000 with Inserts 61.231.11 and 61.232.11
Pin assignment: motor with a motor temperature sensor
Figure 15: Pin assignment „motor with a motor temperature sensor [X6]“
Pin
Name
Specification
A
U
Motor phase U
B
V
Motor phase V
C
W
Motor phase W
PE
PE
Protective earth conductor of the motor
1
MT+
Motor temperature
2
MT-/ DSL-
Motor temperature sensor -
3
BR+
Holding brake +
4
BR-
Holding brake -
5
DSL+
Mounting Instructions BL 4000-M and BL 4000-D
Page 40 of 95
Содержание 9200-4104-2000
Страница 89: ...9 Appendix BL 4800 M BL 4800 D Mounting Instructions BL 4000 M and BL 4000 D Page 89 of 95 ...
Страница 91: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 91 of 95 ...
Страница 93: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 93 of 95 ...
Страница 94: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 94 of 95 ...
Страница 95: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 95 of 95 ...