6 Technical data
Compliance with the pollution degree rating
The integrated safety technology requires compliance with pollution degree rating 2 and
thus a protected enclosure (IP54). This must always be ensured through appropriate
measures.
Use in residential environment
In a residential environment, servo drives of the BL 4000-M / BL 4000-D device family
can cause high-frequency interference, which makes interference suppression
measures necessary.
Maximum housing temperature
Depending on the installation, the servocontroller is additionally heated by the motor, for
example. The following housing temperatures must not be exceeded under any
circumstances:
Characteristic
BL 4840-M
BL 4840-D
BL 4104-M
BL 4104-D
Maximum housing temperature
82 °C
81 °C
85 °C
93 °C
Dimensions and weight
*)
Characteristic
BL 4000-M
BL 4000-D
Dimensions including the
mounting plate (H*W*D)
125 mm*80 mm*65 mm
127 mm*117 mm*114 mm
Housing dimensions (H*W*D)
125 mm*80 mm*65 mm
125 mm*80 mm*65 mm
Weight
approx. 0.7 kg
approx. 1.0 kg
*)
Device dimensions without the mating connector.
Mounting Instructions BL 4000-M and BL 4000-D
Page 63 of 95
Содержание 9200-4104-2000
Страница 89: ...9 Appendix BL 4800 M BL 4800 D Mounting Instructions BL 4000 M and BL 4000 D Page 89 of 95 ...
Страница 91: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 91 of 95 ...
Страница 93: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 93 of 95 ...
Страница 94: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 94 of 95 ...
Страница 95: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 95 of 95 ...