9
Dimensions (LxWxH)
mm
580x575x508
Weight
kg
30
Air duct connections
mm
Ø160
Water connections (compression fittings)
mm
Ø15
Condensate outlet (hose connection)
“
3/4
Maximum allowed water pressure
MPa
1.0
Maximum allowed water temperature in tank
°C
90
Allowed flow range external circulation pump
(not included)
I/hr
200-600
Refrigerant/quantity
-/kg
134a/0.65
Electrical connections
V/Hz
230/50 (L1, N, G)
Fuse size
A
10 (13)
Max. water temperature (heat pump only)
°C
60
Max. water temperature (heat pump and immer-
sion heater)
°C
65
Air flow range (@100 Pa)
m3/h
100-330
Temperature range for compressor operation
°C
-5 – + 35
Sound level 2 m in front om unit at 100% air flow
dB(A)
44
COP acc. to EN-16147 class L , 7°C inlet air
-
2.4
COP acc. to EN-16147 class L , 20°C inlet air
-
3.3
3.6 Performance data
Performance specified for heating of domestic water from 10°C (cold water) to 52.5°C (domes-
tic water) in a connected water tank of 300 l and extract air temperature 7°C: