MI 3108 EurotestPV
Instrument operation
22
Instrument is overheated. The measurement is prohibited until the
temperature decreases under the allowed limit.
Result(s) can be stored.
High electrical noise was detected during measurement. Results may
be impaired.
L and N are changed.
Warning!
High voltage is applied to the test terminals.
Warning!
Dangerous voltage on the PE terminal! Stop the activity
immediately and eliminate the fault / connection problem before
proceeding with any activity!
Test leads resistance in Continuity measurement is not compensated.
Test leads resistance in Continuity measurement is compensated.
High resistance to earth of test probes. Results may be impaired.
Too small current for declared accuracy. Results may be impaired.
Check in Current Clamp Settings if sensitivity of current clamp can be
increased.
Measured signal is out of range (clipped). Results are impaired.
Fuse F1 is broken.
External DC voltage is detected. Measurements in this operating mode
are blocked.
4.1.4 Results
Measurement result is inside pre-set limits (PASS).
Measurement result is out of pre-set limits (FAIL).
Measurement is aborted. Consider displayed warnings and messages.
4.1.5 Sound warnings
Continuous sound
Warning!
Dangerous voltage on the PE terminal is detected.
4.1.6 Help screens
HELP
Opens help screen.
Help menus are available in all functions. The Help menu contains schematic diagrams
for illustrating how to properly connect the instrument to electric installation or PV system.
After selecting the measurement you want to perform, press the HELP key in order to
view the associated Help menu.