MI 3108 EurotestPV
Technical specifications
109
0
550
1
(2 % of r 2 digits)
Result type ........................................ True r.m.s. (trms)
Nominal frequency range .................. 0 Hz, 14 Hz
500 Hz
11.7.3 Frequency
Measuring range (Hz)
Resolution (Hz)
Accuracy
0.00
9.99
0.01
(0.2 % of r 1 digit)
10.0
499.9
0.1
Nominal voltage range ...................... 10 V
550 V
11.7.4 Online terminal voltage monitor
Measuring range (V)
Resolution (V)
Accuracy
10
550
1
(2 % of r 2 digits)
11.8 . TRMS Clamp current
Instrument
Maximum voltage on C1 and P/C2 measuring inputs…3 V
Nominal frequency ............................ ..0 Hz, 40 Hz
500 Hz
AC current clamp A1018
Range = 20 A
Measuring range (A)
Resolution (A)
Accuracy*
0.0 m
99.9 m
0.1 m
(5 % of r 5 digits)
100 m
999 m
1 m
(3 % of r 3 digits)
1.00
19.99
0.01
(3 % of reading)
Range = 200 A
Measuring range (A)
Resolution (A)
Accuracy*
0.00
0.09
0.01
indicative
0.10
19.99
0.01
(3 % of r 3 digits)
20.0
199.9
0.1
(3 % of reading)
AC current clamp A1019
Range = 20 A
Measuring range (A)
Resolution (A)
Accuracy*
0.0 m
99.9 m
0.1 m
indicative
100 m
999 m
1 m
(5 % of reading )
1.00
19.99
0.01
(3 % of reading)