12.3
Changing the measuring range – 4 to 20 mA signal
Set the desired measuring range using the 4 buttons.
Action
Display
Input/output
1.
Press INC, then
5x SET and
1x SHT.
A_000000
Flow at 20 mA
Example: A_002500 = 2500 m
3
/h (flow
at 20 mA)
•
Change the digit with INC
•
Change the position with SHT.
2.
Press RST.
SPA_0000
User password 2
•
Enter 1111 using INC (digit) and
SHT (position)
3.
Press RST.
EEP_SuCC
Data has been saved successfully
EEP_Err
Error when saving
12.4
Changing the standard conditions (p and T)
Set the desired standard values for the pressure and temperature using the 4 buttons.
Action
Display
Input/output
1.
Press SHT, then
SET.
PASS_0000
User password 1
•
No entry is required.
2.
Press 2x SET.
000.0
Standard temperature Tn in°C (DE: 0°C)
P_101.325
Standard pressure pn in kPa (DE:
101.325 kPa)
•
Change the digit with INC
•
Change the position with SHT.
3.
Press RST.
SPA_0000
User password 2
•
Enter 1111 using INC (digit) and SHT
(position)