9.2
Replacing the battery
Note:
•
Only special lithium batteries from Metreg Technologies GmbH may be used.
•
Lithium batteries are subject to special safety rules with respect to their handling,
transport and storage. These rules must be observed. Especially due to their high
energy density, there is risk of fire if the batteries are handled incorrectly.
•
The cable connections (red & black) must NOT touch each other or be short
circuited. There is an acute risk of fire.
Attention: This also applies to replaced batteries!
•
The battery may only be replaced by a person trained in explosion protection.
•
The explosion protection regulations in the relevant country must be observed.
•
It is not permitted to replace the battery in a potentially explosive atmosphere.
•
No data transmission is possible while the battery is being replaced.
Order text
Order no.
Replacement set
Consisting of:
1x meter seal
1x lithium battery
1x instructions for
replacing the battery
88000255
Warning:
Ensure that there are no short circuits
when replacing the battery.
Warning:
The battery may only be replaced in
an Ex zone if it has been guaranteed that the
area is Ex-free.
Fig. 5 Rear of the electronic meter index head