The mixer should be plugged into a switched socket which isolates all poles and has 

a minimum contact clearance of 3mm and located close to the mixer for use in an 

emergency and to facilitate servicing.

The machine must be incorporated into a potential equalization system.

The leakage current for this appliance is no greater than 1 mA/KW.

If the electrical supply cable to the machine becomes damaged, it must be replaced 

by a specification or higher and suitable for the Mixer’s motor load.

The ground wire is fixed to the machine and this connection must be kept intact.

CAUTION: The mixer MUST be grounded.

• 

The minimum requirement for all electrical equipment is correct operation between 
air temperature of +5°C and +40°C.

• 

Electrical equipment is capable of operating correctly when the relative humidity does 
not exceeding 95% at a maximum temperature of +40°C.

• 

Electrical equipment is capable of operating correctly at altitude up to 1000m.

• 

Electrical equipment is designed to withstand to protected against the effects of 
transportation, and storage temperature within a range of -25°C to +55°C and 
for short 

periods not exceeding 24h at up to +70

°C

.

OPERATING INSTRUCTIONS

Before using the mixer

Before using the mixer, ensure that all users are familiar with the correct operation of 

the machine. In particular, care should be taken to ensure that the bowl and mixing tools 

are correctly fitted and that the bowl guard is in position prior to starting the machine.

Safety at work

NEVER place your hand or any kitchen utensil in the bowl whilst the mixer is 

in operation.

• 

Keep hands, hair and clothing away from moving parts.

• 

Isolate the machine from the electrical supply by removing the plug from the 
socket before cleaning, servicing or adjusting any parts or attachments.

• 

Do not use the machine with any cover or guard removed.

• 

Certain operator notice advising about the safe use of this mixer is attached to 
the machine.

Содержание SP-30HA-W

Страница 1: ...on manual Mixer with removable safety guard Metos Marine SP 30HA Y 440 3 60 Hz SP 30HA W 480 3 60 Hz SP 40HA U 440 3 60 Hz SP 40HA W 480 3 60 Hz 4025038 4025038MO 4025041MM 4025041MO 15 05 2015 SP 30H...

Страница 2: ...emovable Bowl Guard 8 Open Closing the Bowl Guard 8 Removing and Attaching the Bowl Guard 9 Controls 9 Timed operation 9 Untimed operation 10 CAPACITY 10 SPEED SELECTION 10 ATTACHMENTS 11 NOISE TEST R...

Страница 3: ...ng and keep hands hair and clothing away the moving parts NEVER use an extension cord to connect electrical power Make sure the safety guard is closed and bowl is lifted to right position before opera...

Страница 4: ...P 30HA SP 40HA 15 05 2015 OVERALL VIEW OFTHE MIXER A Bowl B Removable Bowl Guard C Planetary Hub E Control Panel F Gear lever G Addition Chute H Bowl lift Wheel I Bowl Cradle Control Panel A Emergency...

Страница 5: ...of your electrical connection The mixer is supplied with a trailing lead fitted with a molded plug If the style of plug is unsuitable for the socket you plan to use the plug must be cut off and replac...

Страница 6: ...aximum temperature of 40 C Electrical equipment is capable of operating correctly at altitude up to 1000m Electrical equipment is designed to withstand to protected against the effects of transportati...

Страница 7: ...ter the control button has been pressed again This arrangement ensures that when the supply is restored the machine cannot restart on its own Careful handling of bagged products by minimizing the heig...

Страница 8: ...ontact licensed elect rician immediately to remedy incorrect wiring Bowl lift Bowl Guard The bowl cradle and bowl guard are electrically interlocked so that the machine will only operate with the bowl...

Страница 9: ...the ring catch on the mixer Fig D To reattach the bowl guard line up the ring catch on the left of the mixer lift guard gently into place and rotate the guard s lower handle counterclockwise until it...

Страница 10: ...d can then be selected before restarting the machine by pressing the Green Start Button The speed selected depends largely on the quantity and consistency of the product It is recommended that mixing...

Страница 11: ...e attachments when mixing The recommended speed range for some of the attachments available is shown in table below Recommended speed 1st gear 2nd gear 3rd gear V99S Veg Prep VH 12 Mincer V99S Vegetab...

Страница 12: ...as this could prevent correct location of the bowl For the same reason ensure that the beater shaft and each of the sockets on the tools are cleaned thoroughly The bowl and tools should be washed in...

Страница 13: ...while not using the mixer Gearbox Lubricant Please refill the lubricant inside the gearbox every 5 years We recommended that this servicing or maintenance work must be carried out by trained technicia...

Страница 14: ...of gear put in gear Mixer becomes noisy 1 Check bowl and tools 2 Check work surface 3 Check bearing for wear 4 Check gearbox 5 Check planetary unit 1 Ensure that bowl and tool are correctly seated 2...

Страница 15: ...d in of solids Example A basic recipe contains 1 kg of solids and 0 4 kg of liquid This gives AR 0 4 kg x 100 40 1 kg If for instance it is required to use the maximum capacity of themixer the calcula...

Страница 16: ...16 Metos Marine Mixer SP 30HA SP 40HA 15 05 2015 TECHNICAL SPECIFICATIONS DIMENSIONS SP 30 DIMENSIONS SP 40...

Страница 17: ...15 05 2015 17 Metos Marine Mixer SP 30HA SP 40HA...

Страница 18: ...PARTS Wiring Diagram SP 30HA 400V 3 phase 60 Hz Wiring Diagram SP 30HA 440V 3 phase 60 Hz Wiring Diagram SP 30HA 480V 3 phase 60 Hz Wiring diagram SP 40HA 440V 3 phase 60 Hz Wiring diagram SP 40HA 48...

Страница 19: ...0HA Wiring Diagram 400V GROUND OFF SWITCH ON SWITCH VS LAMP TIMER OVERLOAD RELAY CONTACTOR 3 FUSE TRANSFORMER TERMINAL BLOCK MOTOR POWER SUPPLY GROUND 1HP MICROSWITCH SAFTY COVER MICROSWITCH HEIGHT AD...

Страница 20: ...30HA Wiring Diagram 440V GROUND OFF SWITCH ON SWITCH VS LAMP TIMER OVERLOAD RELAY CONTACTOR 3 FUSE TRANSFORMER TERMINAL BLOCK MOTOR POWER SUPPLY GROUND MICROSWITCH SAFTY COVER MICROSWITCH HEIGHT ADJU...

Страница 21: ...M...

Страница 22: ...M...

Страница 23: ...M...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...200S3...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ...WH 6FUHZ 0 3ODVWLF DQGOH 7RXFK 0DVV 6 6 5LQJ 5HPRYDEOH 7 SH 6 6 DQGOH 9HUWLFDO 6 6 LUHV RUL RQWDO 6 6 LUHV KXWH 6 6 6 6 RZO XDUG VVHPEO 5HPRYDEOH 7 SH 6 6 3ODVWLF 6OLGH 6KHDWK VVHPEO 5HPRYDEOH 7 SH 6...

Страница 36: ......

Отзывы: